Usermanagement - Siemens SITOP UPS1600 Manual

Hide thumbs Also See for SITOP UPS1600:
Table of Contents

Advertisement

Display name
AlarmBattery
TemperatureLow
AlarmFuseBroken
AlarmNewBattery
Detected
BufferTime
BufferingEndVoltage
ChargeCurrent
ChargeEndVoltage
ChargeTotalCurrent
ModuleCalculated
Capacity
ModuleCalculated
Health
ModuleCapacity
ModuleChange
Recommended
ModuleCompound
ModuleConnection
Fault
ModuleMax
Temperature
ModuleMin
Temperature
ModuleStandbyTime
ModuleStateLed
ModuleTemperature
ModuleTotal
CulledCurrent
3.8.6.22

UserManagement

Display name
AddUser
ChangeUserPassword Method
DeleteUser
UsermanagementUser
1 ... 16
SITOP UPS1600 / UPS1100
Manual, 04.2017, A5E37775406-8-76
Data type
Definition
Boolean
PropertyType
Boolean
PropertyType
Boolean
PropertyType
UInt32
AnalogItemType Desired buffering time before device switches off
Float
AnalogItemType When battery voltage is lower than this voltage, the battery
Float
AnalogItemType Actual charging current used to charge battery.
Float
AnalogItemType Battery voltage when charging changes to trickle charging.
Float
AnalogItemType Battery-specific data: Total charge to the battery during its
Float
AnalogItemType Available battery capacity
Byte
AnalogItemType State of health (SoS) as percentage of the rated capacity
Float
AnalogItemType Capacity
Boolean
PropertyType
Enumeration
MultiState
DiscreteType
Boolean
PropertyType
Sbyte
AnalogItemType Maximum specified operating temperature of the battery.
Sbyte
AnalogItemType Minimum specified operating temperature of the battery.
UInt32
AnalogItemType Battery-specific data: Time for which battery was connected
Object
Sitop_1600_
LedType
Sbyte
AnalogItemType Battery temperature
Float
AnalogItemType Battery-specific data: Time for which battery was connected
Data type
Definition
Method
Method
Method
Method
Method
SitopUserType
SitopUserType
Description
Battery temperature too low - reduced output current
Fuse is defective.
A new battery was connected. The battery will be included
in the calculation of the total capacity and the charge pa-
rameters.
charge is no longer sufficient. Buffering is stopped.
Battery is charged 100%.
service life
Battery capacity is insufficient to achieve the specified buffer
time.
Connected device
Connection to battery interrupted - check connection and
fuse
but no power was consumed.
ModuleStateLed
and power was consumed.
Description
Adds a user.
Changes the password for the user.
Deletes the user.
Engineering and remote access
3.8 OPC UA server
179