■Master station and slave stations (except for local stations)
Master operation
Station No.0
Master station
RX, RWr
Station
No.0
Station
No.1
Station
No.2
Station
No.3
RY, RWw
Range of the
station No.0
sending data
Range of the
sending data to
the station No.1
Range of the
sending data to
the station No.2
Range of the
sending data to
the station No.3
Station No.0
Master station
RX, RWr
Station
No.0
Station
No.1
Station
No.2
Station
No.3
Disconnected
RY, RWw
Range of the
station No.0
sending data
Station
No.1
Station
No.2
Station
No.3
Data sent from the master operating station
Data sent from slave stations
Station No.1
Station No.2
Slave station
Slave station
RX, RWr
Range of the
station No.1
sending data
RX, RWr
Range of the
station No.2
sending data
RY, RWw
Station
No.1
RY, RWw
Station
No.2
Switch
Station No.1
Station No.2
Slave station
Slave station
RX, RWr
Range of the
station No.1
sending data
RX, RWr
Range of the
station No.2
sending data
RY, RWw
Station
No.1
RY, RWw
Station
No.2
Area where data is sent to other stations
Submaster
operation
Station No.3
Submaster
station
RX, RWr
Station
No.0
Station
No.1
Station
No.2
Station
No.3
RY, RWw
Station
No.0
Station
No.1
Station
No.2
Range of the
station No.3
sending data
Master operation
Station No.3
Submaster
station
RX, RWr
Station
No.0
Station
No.1
Station
No.2
Station
No.3
RY, RWw
Range of the
sending data to
the station No.0
Range of the
sending data to
the station No.1
Range of the
sending data to
the station No.2
Range of the
station No.3
sending data
1 FUNCTIONS
1.6 Submaster Function
1