■Setting in the local station
Connect the engineering tool to the CPU module to be set as the control system and set the parameters.
In a redundant system, the same program and parameter are written to both systems. A new project does not need to be
created for the standby system.
1.
Set the CPU module and add the module labels of the CPU module. The setting method of the CPU module and addition
method of the module label are the same as those for the redundant master station. ( Page 95 Redundant master
station)
2.
Set the redundant function module. The setting method for the redundant function module is the same as the one for the
redundant master station. ( Page 95 Redundant master station)
3.
In the I/O assignment setting, set the RJ71GF11-T2 for slot No.1.
4.
Click the [OK] button to add a module label of the RJ71GF11-T2.
5.
Set the refresh settings as follows.
[Navigation window]  [Parameter]  [Module Information]  [RJ71GF11-T2(SR)]  [Basic Settings]  [Refresh
Settings]
1 FUNCTIONS
102
1.7 Redundant System Function