MDC System
Options
DFDCI
Function Key Descriptions
F3 - PREV SYS
F4 - NEXT SYS
F9 - MDC SYS REMOTE
Field Definitions
MDC System
System Pretime (ms)
Preamble During Pretime
230
From the MAIN MENU, press F4, F6, F4, F3 and then F9 to access this
screen.
MOTOROLA Radio Service Software
MCS
Model:
...CONV:MDC:SYSTEMS:OPTIONS
MDC System.........1
System Pretime (ms)...........500
Preamble During Pretime...Enabled
Inter-Packet Time (ms)........100
Limited Patience (sec).........60
DOS (Data Squelch)........Enabled
Operation...........1200/1800 Hz
Coast Time (ms)...........267.00
Sel Call Reset.......Auto w/ Carr
Auto Reset Time (sec)..........5
F1
F2
F3
F4
HELP
PREV
NEXT
SYS
SYS
The settings shown on this screen apply only to the MDC system numerically
identified on the screen.This screen contains more options for MDC
systems. Press Tab to select the desired field, or press the desired
function key (F1 - F10). If a field is highlighted, use the UP/DOWN
arrow keys to select the desired choice or value.
Accesses the previous system.
Accesses the next system.
MDC SYS REMOTE - is used to change and view parameters associated
with MDC System Remote Monitor/Radio Trace features.
Use the UP/DOWN arrow keys to change the MDC system or directly
enter the system number.
Use the UP/DOWN arrow keys to choose a value or enter the desired
value directly. This is the amount of pre-time used before the first MDC
packet is transmitted. If an RAC packet is transmitted, then the system
pre-time is used before the first MDC packet after the RAC packet.
Valid entries range from 0 (zero) to 6350 ms in 50-ms increments.
The default is 400.
Use the UP/DOWN arrow keys to enable/disable the preamble
sequence which will precede voice transmissions.
The default is Disabled.
Enter or Scroll to Select Value.

MDC SYSTEM OPTIONS

------------------
Emergency
Polite Retries..................5
Impolite Retries...............15
Emer Prio Tx Inhibit......Enabled
Emer Limited Patience (sec)...60
Global Tx Multiplier..... Enabled
Tx Multiplier...................1
RAC (Repeater Access Code)
Pretime (ms).................200
Ack Alert Tone...........Enabled
Preambles......................5
Sidetone................ Enabled