Mitsubishi Electric L02SCPU User's Manual And Reference page 379

Melsec-l series, cpu module
Table of Contents

Advertisement

Added function
Predefined protocol function
Serial communication function (RS-232
*1
adapter, RS-422/485 adapter)
Operation mode setting at double block
*1
START (SFC)
Increase in the number of steps (SFC)
1K point setting for the step relay (S)
Step comment readout instruction
(S(P).SFCSCOMR), transition condition
comment readout instruction
*1
(S(P).SFCTCOMR)
Online change (inactive blocks) (SFC)
Storing MAC address in the special register,
setting and storing IP address in the special
*1
register
*1
RS-422/485 adapter
Simple CPU communication function
compatibility (Support by F-series FX3)
Pointer points extension compatibility for the
*1
Auto assignment device
Support of the iQ Sensor Solution function
(data backup/restoration only) for the CC-Link-
AnyWireASLINK bridge module
*1
(NZ2AW1C2AL)
*1
Real-time monitor function
Support of the iQ Sensor Solution function
(data backup/restoration only) for the CC-Link
*1
IE Field Network module
*1
LA1S extension base unit
File transfer function (FTP client)
*1
E-mail send/receive function
CC-Link IE Field Network Basic function
*1
SLMP frame send instruction
*1
Some models do not support these functions. For the availability, refer to the corresponding section or manual of each
function.
*2
For the versions of the intelligent function modules that support the function, refer to the manual for the intelligent
function module used.
*3
GX LogViewer with a software version of 1.37P or later is required.
*4
Only the Built-in Ethernet port LCPU supports this function.
Serial No. (first 5
digits) of CPU
module
*1
"15102" or later
*1
*1
"16042" or later
"16072" or later
"16112" or later
*1
*4
"18112" or later
GX Works2 version
Page 215, Section 3.37
Page 227, Section 3.38
1.501X or later
MELSEC-Q/L/QnA Programming
Manual (SFC)
MELSEC-L CPU Module User's
Manual (Hardware Design,
Maintenance and Inspection)
1.501X or later
MELSEC-L CPU Module User's
Manual (Built-In Ethernet Function)
Page 362, Appendix 1.2 (8)
1.513K or later
Page 234, Section 3.39, iQ Sensor
Solution Reference Manual
Page 150, Section 3.21, GX
*3
LogViewer Version 1 Operating
Manual
Page 234, Section 3.39, iQ Sensor
Solution Reference Manual
MELSEC-L LA1S Extension Base Unit
User's Manual
1.525X or later
MELSEC-L CPU Module User's
Manual (Built-In Ethernet Function)
CC-Link IE Field Network Basic
1.555D or later
Reference Manual
MELSEC-L CPU Module User's
Manual (Built-In Ethernet Function)
: Function that is not related to serial No. or software version
APPX
Reference
A
377

Hide quick links:

Advertisement

Table of Contents
loading