3.36.1

Batch save

This function saves data (such as program file and parameter file) in the CPU module to an SD memory card using a
display unit.
(1) Execution method
The function can be executed using a display unit. For the operating method of the display unit, refer to 
Page 280, Section 4.7.3.
(2) Folders to be used
When the function is executed, a new folder will be created under the "SaveLoad" folder within the root directory.
If there is no "SaveLoad" folder, it will be created upon execution of the function.
The "SaveLoad" folder can store up to 100 folders.
(a) Folder name
The created folder is automatically named as follows.
Remark
The range of the number at the end of the folder name is 00 to 99. The smallest number available will be assigned
automatically. For example, if two folders, "20120401_00" and "20120401_02", have already existed and the batch save
function is executed on April 2, 2012, the name of the new folder will be "20120402_01".
YYYYMMDD_**
Serial number (00 to 99)
Saved date (2 digits)
Saved month (2 digits)
Saved year (4 digits)