(2) Device test procedure
1.
Connect a personal computer to the CPU module
2.
Display a program in ladder mode
3.
Switching to the monitor mode
[Online]  [Monitor]  monitor mode
4.
Select [Local device monitor] from the monitor window.
(3) Number of programs that can be monitored/tested
Local devices of 16 programs can be simultaneously monitored or tested from multiple programming tools.
(4) Precautions
• One programming tool can monitor or test local devices in one program at a time. Local devices in multiple
programs cannot be monitored or tested simultaneously.
• When local devices in a stand-by type program are monitored, data in local devices are saved and restored.
For this reason, the scan time increases.
• When local devices in a fixed scan execution type program are monitored, data in local devices cannot be
acquired and "0" is displayed.