(a) Using a RUN contact
Set a RUN contact.
Project window [Parameter] [PLC Parameter] [PLC System]
Set a device used as a contact.
The remote RUN/STOP operation can be performed by turning on/off the set RUN contact.
• When the RUN contact is turned off, the CPU module status changes to RUN.
• When the RUN contact is turned on, the CPU module status changes to STOP.
(b) Using a programming tool
Open the "Remote Operation" dialog box.
[Online] [Remote Operation]
Select "RUN" or "STOP"
for execution.
A remote RUN operation executed only from the programming tool that has executed a remote STOP operation to the CPU
module.
(c) By an external device using the MC protocol
Use MC protocol commands.
MELSEC Communication Protocol Reference Manual
(d) Using the link dedicated instruction of the CC-Link IE Field Network master/local
module
Use the link dedicated instruction of the CC-Link IE Field Network master/local module.
MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual
CHAPTER 3 CPU MODULE FUNCTIONS
3
113