Mitsubishi Electric L02SCPU User's Manual And Reference page 367

Melsec-l series, cpu module
Table of Contents

Advertisement

Parameter
Item
No.
0409
Switch Setting
Error Time
0403
Output Mode
PLC
Operation
4004
Detailed
Mode at H/W
Setting
Error
I/O
0405
Response
Time
Select PLC type
Select module
*1
For the L02SCPU, L02SCPU-P, L02CPU, and L02CPU-P, 1024 points cannot be set.
*2
Since the branch module and the branch module (for LA1S Extension) have no I/O points, the number of I/O points and
the start X/Y cannot be set.
Description
Set the switches of the built-in I/O
function or intelligent function
H
modules.
Set the output status for the case of a
H
stop error in a CPU module.
Sets an operation mode of the CPU
module when a hardware error (CPU
module detects SP.UNIT DOWN)
H
occurred in an intelligent function
module.
Set a response time for the input
H
module or I/O combined module.
Sets the model of the connected CPU
module automatically in the "I/O
Assignment" area by selecting the
module from the pull-down menu.
Sets the model name, points, and start
I/O number of the selected module
automatically in the "I/O Assignment"
area by selecting the module from the
pull-down menu.
Setting range
Clear/Stop
Stop/Continue
Select 1ms, 5ms, 10ms, 20ms, or
70ms.
APPX
Default
Reference
Clear
Stop
Page 41,
Section 2.2
10ms
365
A