Quantum Data 801GC, 801GF, 801GX Owner's And Programmer's Manual page 287

Portable video signal generators
Table of Contents

Advertisement

SEQK
Classification:
Command Syntax:
Limits:
Query Syntax:
Limits:
Query Response:
Description:
Other Required Cmds:
Example:
SEQL
Classification:
Command Syntax:
Limits:
Query Syntax:
Limits:
Query Response:
Description:
Other Required Cmds:
Example:
SEQuence Kill
Sequence memory management
SEQK <name>
<name> = a valid MS-DOS filename
(8 characters minus any extension)
SEQK? <name>
<name> = a valid MS-DOS filename
(8 characters minus any extension)
0 or 1
The SEQK command deletes a sequence by name. The query
returns a one (1) if the named sequence can be deleted. If sequence
is read-only or nonexistent, the query returns a zero (0).
None
S E Q K
M Y _ S E Q
/ /
D e l e t e
/ /
" M Y _ S E Q "
SEQuence Load
Sequence memory management
SEQL <name>
<name> = a valid MS-DOS filename
(8 characters minus any extension)
SEQL? <name>
<name> = a valid MS-DOS filename
(8 characters minus any extension)
0 or 1
The SEQL command copies the sequence having a name equal
to <name> from sequence memory into the sequence edit buffer.
The query returns a one (1) if the named sequence can be loaded,
otherwise a zero (0) is returned.
An SEQU command must be executed after the SEQL command
to start running the sequence.
S E Q L
M Y _ S E Q
/ /
L o a d
/ /
e d i t
b u f f e r
S E Q U
/ /
S t a r t
r u n n i n g
/ /
t h e
b u f f e r
s e q
c a l l e d
" M Y _ S E Q "
d i r
i n
t h e
s e q u e n c e
i n
6-161

Hide quick links: