KNOB
Classification:
Command Syntax:
Limits:
Query Syntax:
Description:
Other Required Cmds:
Example:
LCDS
Classification:
Command Syntax:
Query Syntax:
Query Response:
Description:
Other Required Cmds:
Example:
rotate KNOB
System parameter setting
KNOB <number> <clicks>
<number>
1 = upper Format knob
2 = lower Image knob
<clicks>
positive integer = knob clicks in a clockwise direction
negative integer = knob clicks in a counterclockwise
direction
None
The KNOB command has the same affect on generator operation
as if an operator were manually turning either the "Format" or
"Image" knobs on the generator.
When a sequence is running, the "Format" knob loads sequences
from the directory selected by the SEQP command. Clockwise
rotation increases the index pointer for the directory. The "Image"
knob is used to go back and forth through the sequence steps.
Clockwise rotation selects higher step numbers.
None
K N O B
2
1
/ /
M o v e
/ /
C W
LCD Status
System parameter setting
None
LCDS?
Response in normal format/image selection mode...
H<Horiz Rate>
<Fmt Mem Loc> = <Fmt Name> <cr><lf>
V<Vert Rate>
<Img Mem Loc> = <Img Name>
The LCDS? query returns text string data that matches what is
shown in the LCD window of the generator.
None
L C D S ?
/ /
R e t u r n
/ /
b e l o w
/ /
H 3 2
1 5 = V G A _ m 3
/ /
V 6 0
5 1 = S M P T E 1 3 3
I m a g e
k n o b
1
c l i c k
t e x t
s i m i l a r
t o
< c r > < l f >
t e x t
6-147
Need help?
Do you have a question about the 801GC, 801GF, 801GX and is the answer not in the manual?