Figure 75: Scanner Settings pane
2.
The Autoconnect CINR threshold field displays the Carrier to Interference + Noise Ratio threshold.
The Connect to recent used BS field can be set to connect to a recently used base station. The default
3.
option is No.
The Scanner Table lists the frequencies scanned by the CPE to locate its base station. The Scanner Table
4.
displays the following information:
Table: Scanner Table fields
Column
Priority
Bandwidth [MHz]
Start frequency [kHz]
Step [kHz]
End frequency [kHz]
PUSC Mode
5.
The Scan Report field displays a list of base stations located by the scan. The list includes the following
information for each base station:
• the base station MAC address
• the base station frequency
Scanner Settings
Description
Sets the priority for the scanning table entry. Priority is ranked in numeric order.
Values: A numeric value.
Displays the bandwidth of the scanning table entry.
Values: 3.5MHz | 5MHz | 7MHz | 10MHz
Displays the start of the scanning range as a frequency in kilohertz.
Displays scanning increment in the scanning range, in kilohertz.
Displays the end of the scanning range as a frequency in kilohertz.
Displays the PUSC mode. The base station must be set to a PUSC mode (using the
Frame Settings pane in the Base Station) for this feature to work. You can then select
which PUSC mode channels to connect to.
Values: PUSC3 | PUSC2 | PUSC1 | All Subchannels