Chapter 6
CPE Management Interface
Figure 48: DSCP Marking pane
3.
In the DSCP marking [0-63] field, type a value in the range of 0 to 63. The default value is 48.
Click the Apply button.
4.
Section 6.2.8

Software Version Management

Permanent memory storage is organized in two memory banks, "1" and "2". Two versions of the operating system
software can be stored on the CPE, one in each memory bank. Each memory bank is designated as either
the "Primary" or "Secondary" memory bank. When you reset or reboot the CPE, it always runs the software
installed in the "Primary" bank. The CPE web console provides controls to change the "Primary" and "Secondary"
designations on the memory banks, and to reboot the CPE using the "Secondary" memory bank for testing.
Software saved in one bank can be copied to the other, allowing you to create backups and to restore or update
versions as required.
This section describes how to manage CPE software versions 4.2 and later, including how to upload and
download files, manage the memory banks and their "Primary" and "Secondary" designations, and how to backup
and restore the operating system.
Section 6.2.8.1

Upgrading CPE Software

For safety and reliability, the CPE software upgrade process consists of the following steps, with checks and
verification at several stages:
1.
Load the new software image to the secondary memory bank:
• Configure the FTP server from which the new software files will be downloaded (see
"Downloading CPE
• Download the software update files to the secondary memory bank (see
CPE
Software").
• Verify that the downloaded software files have been correctly saved to the secondary memory bank (see
Section 6.2.8.5, "Managing the Secondary Memory
2.
Perform a trial run of the new software image:
On the SW Properties pane, click Run Secondary.
54
Software"):
Section 6.2.8.3, "Downloading
Bank").
RUGGEDCOM WiN5100/WiN5200
User Guide
Section 6.2.8.3,
Software Version Management