RUGGEDCOM WiN5100/WiN5200
User Guide
The CPE will reset and load the software image in the secondary memory bank. This process will take
approximately two minutes.
3.
Commit the new software image as the new default software:
Again on the SW Properties pane, click Set As Primary in order to set the current memory bank (currently
denoted Secondary) as Primary. Doing so will cause the software in the memory bank newly designated
Primary to be run by default on bootup.
Section 6.2.8.2

Viewing Software Properties

The SW Properties pane displays information about the software loaded into each CPE memory bank. On this
pane, you can reboot the CPE from the secondary bank, set the current bank as the primary bank, and reboot the
CPE.
Procedure: Viewing software properties
1.
Click the Management button. The System Functions pane appears.
2.
In the options pane, click the SW Upgrade link. The SW Properties pane appears.
Figure 49: SW Properties pane
3.
The SW Properties pane displays the following information:
Table: SW Properties
Field
Current Active Bank
Viewing Software Properties
Description
Displays the name of the memory bank from which the CPE software is running.