Chapter 6
CPE Management Interface
Field
Current SW Location
Primary SW Version
Primary SW Location
Primary CDC
Primary UV
Secondary SW Version
Secondary SW Location
Secondary CDC
Secondary UV
Configuration Changes Counter
4.
The following operations can be performed from this pane:
• Run Secondary — Reboot the CPE and run the "Secondary" software image. Reboot a second time to
run the CPE using the "Primary" software image.
• Set as Primary — Set the current running software as the "Primary" image. For example, if the CPE is
running from the "Secondary" image, the "Primary" and "Secondary" designations are exchanged.
• Reboot — Reboot the CPE and run the "Primary" image.
Section 6.2.8.3

Downloading CPE Software

Use the SW Download pane to download CPE software from your FTP server. The CPE downloads all software
to the "Secondary" memory bank.
Procedure: Downloading software
1.
Click the Management button. The Current Status pane appears.
2.
In the options pane, click the SW Upgrade link, and then click the SW Download link. The SW Download
pane appears.
56
Description
Values: Primary | Secondary
Displays the number of the memory bank from which the CPE software is running.
Values: 1 | 2
Displays the version number of the software in the Primary memory bank.
Displays the number of the current Primary memory bank.
Values: 1 | 2
Displays the filename of the CDC (Customer Defaults Configuration) file in the Primary
memory bank.
Displays the filename of the UV (Unique Value) file in the Primary memory bank.
Displays the version number of the software in the Secondary memory bank.
Displays the number of the memory bank selected as the Secondary memory bank.
Displays the filename of the CDC (Customer Defaults Configuration) file in the
Secondary memory bank.
Displays the filename of the UV (Unique Value) configuration file in the Primary memory
bank.
Displays the number of changes made to configuration values on the CPE. This value
only includes changes to configuration values. It does not include events, such as
setting the primary software image or uploading a file.
RUGGEDCOM WiN5100/WiN5200