Normal Operation Flow Chart - Travis Industries Deerfield Service & Troubleshooting Manual

Table of Contents

Advertisement

Normal Operation Flow Chart

Status Light
is flashing –
1 flash/sec.
YES
Press Start:
Does
Combustion
Blower
come on
YES
Does the
push auger
come on?
YES
on
Continue
next page
17602010 - 12/15/17
If it is flashing (2) flashes /sec then
check the UI connection to the PCB.
NO
Check if the UI board is lit up.
If still not working, replace UI.
Check Exhaust Fan status light on
the PCB.
Check Power at quick connects at
the Combustion Blower.
NO
Use a test cord to power the blower
directly to outlet power.
Check pressure Status light
Check wires for damage.
Check the PCB for Push Auger
status light.
Check The voltage at the AC power
pins (see testing AC power)
NO
Use a test cord to power the blower
directly to outlet power.
Check wires for damage
Page 55