AC Status Lights

The status lights for the AC components tell you when the board is sending power to the component, not if the
component is working properly. If you find that a particular component is not working (i.e. the push auger motor is not
turning), check the status light for the component and see if the board is sending power. If the light is on, use a
Multimeter to test the power at the AC Pins on the board that corresponds to the component in question (see section
"Testing AC Power at the Board"). If the appropriate power is present at the pins on the PCB, test voltage at the
component and see if power is reaching it. If power is not present at the component, the stove most likely has a wiring
harness issue and you should test continuity between the board and the component. If power is present, the
component is likely bad. Use a test cord to supply power directly to the component to verify your findings.