Appendix C
Fan Voltages and Metering Motor Timing
Voltages and Timings for v1.1.7 FW
LEVEL
1
2
3
4
5
6
7
8
9
10
Use CONV LOW when heat level is 5 or less; use CONV HIGH
otherwise.
METER TIMINGS are in seconds, and represent the OFF time. On time is
45 seconds.
Voltages assume 120Vac power source, measured using a True RMS
voltmeter under load, and are approximate.
CONV
CONV
LOW
HIGH
90
92
93
95
100
105
110
110
110
110
17602010 - 12/15/17
EXHAUST
95
100
100
103
105
105
110
110
115
112
120
115
120
120
120
120
120
120
120
METER
TIMINGS
95
148
124
100
80
63
49
35
22
18
12