7. Push the auger shaft forward so that it is flush with the outer edge of the brass bushing. Slide the bushing
plate up to disengage the tab on the bottom of the plate from the notch in the auger tube (see below).
8. Remove the bushing block by sliding it straight back, out of the end of the auger tube.
9. Go around to the front of the stove. Reach into the end of the push auger tube, pull the auger flight forward
and remove it from the tube.
Push shaft flush
with bushing
Lift up on plate
so tab on plate
releases from the
notch in the tube