Combustion Blower Removal

Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
2. Disconnect the venting from the stove.
3. Open the ash pan door and remove the ash pan from the appliance.
4. Remove the exhaust cover plate by removing the wingnut on the left side and pulling the left side of the plate
forward and pulling the plate free of the stove. Set the wing nut and plate aside for reinstallation.
5. Locate the 6 bolts around the exhaust port in the rear of the ash pan cavity. Depending on the amount of use the
stove has had, you may want to apply penetrating oil and allow it to sit for a few minutes before removing the bolts.
Use a 3/8" nut driver or ratchet for removal. Set the bolts aside for reinstallation.
Remove bolts
17602010 - 12/15/17
Page 21