Travis Industries Deerfield Service & Troubleshooting Manual page 56

Table of Contents

Advertisement

Depending on environmental
conditions, cleanliness of the
stove, fuel quality and condition
of gasket material this process
may take between 4-15
minutes.
Does
Metering
Motor Cycle
On/Off
YES
Is the Igniter
getting hot?
YES
Are the
Pellets
Lighting?
YES
Enjoy the Fire!!!!
17602010 - 12/15/17
• Check the PCB for Push Auger
status light.
• Check The voltage at the AC power
pins (see testing AC power)
• Use a test cord to power the blower
NO
directly to outlet power.
• Check wires for damage Check
Encoder voltages (see section
Testing DC voltage from encoder")
• Check to see if HRD is jammed.
• Check the PCB Igniter status light.
If it is on, the unit is sending power
to the igniter.
• Check The voltage at the AC power
pins (see testing AC power)
• Check voltage at the quick connects
NO
to the igniter.
• Check wires for damage.
• Disconnect wires from the igniter
and test resistance. Should be 52Ω
to 67Ω (out of range = replace)
Check the quality of the fuel.
Check for gasket leaks around
door.
Check for gasket leaks around
glass.
Check for gasket leaks at
NO
combustion blower
Look for obstructions in intake air.
Check for buildup on the burn
platform.
Make sure the burn platform is in
place properly.