Igniter Removal

Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
1. Remove the rear panel of the stove (see rear panel removal).
2. Using a ¼" nut driver remove the zip tie anchor from the back of the stove. The anchor is located just below
and to the left of the right blower (facing the back).
3. Disconnect the two white wires from the wiring harness at the quick connects.
4. Open the front door of the stove and remove the visual deflector and the burn platform (see section "Visual
Deflector and Burn Platform Removal"). .
5. Locate the igniter to the left of the push auger tube.
Zip tie anchor
17602010 - 12/15/17