Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
1.
Remove the both side panels (see section "Side Panel Removal"). Locate the set screw and locking collar between the
bushing plate and the Push Auger Motor (whichever way the set screw is facing is the side you want to perform the rest of
the procedure from (in the example below it is being shown from the right side of the stove)..
2.
The push auger motor is the motor that is directly above the air intake of the stove and behind the HRD assembly. The
auger motor is oriented horizontally.
3.
Use a 3/16" Allan wrench to loosen the retaining screw. If you only remove the screw enough to allow the shaft of the
motor to become free, the collar will stay in place making for easier re installation of the auger motor.
Collar
"D" Shaped
part of Shaft
Auger
Motor
Retaining
Screw
Auger
Shaft
17602010 - 12/15/17