Metering Motor Removal - Travis Industries Deerfield Service & Troubleshooting Manual

Table of Contents

Advertisement

Metering Motor Removal

Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
1.
Remove the left side panel (see section "Side Panel Removal").
2.
Remove the Power Control Board and heat shield (see section "Power Control Board Removal").
Remove the blower (see section "Blower Removal") to gain access to the retaining screw.
3.
Disconnect the two wires on the motor from the wire harness at the quick connects.
4.
Use a 3/16" Allan wrench to loosen the retaining screw. If you only remove the screw enough to allow the shaft of the
motor to become free, the collar and spacer will stay in place making for easier re installation of the auger motor.
NOTE: When re-installing the auger motor make sure that the retaining screw is seated against the flat portion of the
"D" shaped portion of the auger shaft.
Spacer
Collar
Retaining
Screw
17602010 - 12/15/17
OR
Auger
Shaft
"D" Shaped
part pf Shaft
Auger