6. The long flat Molex at the bottom of the board is actually two separate connectors. The smaller of the two is
from the encoder on the push auger motor. The larger connector is from the external thermostat. These
connectors have the same type of tab on it as the User Interface connector. Pry the tab back slightly and
disconnect the connectors from the board.
7. If you are removing the board in order to gain access to other components, you will now want to remove the
metal heat shield Using a ¼" nut driver to remove the (2) screws at the bottom of the shield. When reinstalling
the shield make sure that the green ground wire is reconnected.
Ground Wire
17602010 - 12/15/17