Installing A Non-Hot-Plug Drive - HPE ProLiant ML150 Gen9 User Manual

Table of Contents

Advertisement

Install the drive.
3.
Determine the status of the drive from the drive LED definitions.
4.
To configure arrays, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard
Enterprise website (http://www.hpe.com/info/smartstorage/docs).

Installing a non-hot-plug drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To install the component:
Unlock and remove the tower bezel
1.
Power down the server (on page 17).
2.
Remove all power:
3.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on its side.
4.
Remove the access panel (on page 18).
5.
If installed, remove the PCI air baffle (on page 20).
6.
Remove the system air baffle (on page 22).
7.
Remove the fans (on page 23).
8.
If already installed, disconnect the drive cables from the rear of the drives.
9.
Remove the non-hot-plug drive cage from the chassis:
10.
("Remove the tower
bezel" on page 17).
Hardware options installation 40