6 Operation
6.4 Operating modes
28
1. Start the super speed process by pressing the lift button.
 The loading sequence lasts approx. 15 seconds from the end
position of the furnace door. Loading must be completed within
this time frame. The furnace closes automatically. A countdown
displays the remaining loading time as a guide, before the
furnace closes. If the start/stop button is actuated, the process is
canceled and must be restarted.
2. Place the restoration with the occlusal surface (chewing surface)
facing downward on the crucible.
3. Place the Superspeed covering over the restoration on the crucible.
4. With the help of the crucible fork, remove the crucible with the
restoration and covering, so as to load the furnace.
5. Load the furnace.
 The furnace closes automatically.