Table of contents Dentsply Sirona Operating Instructions CEREC AC Table of contents Dear Customer,....................... Contact data....................General data ......................Structure of the document................2.1.1 Identification of the danger levels ..........2.1.2 Formats and symbols used............Battery warranty................... Legend ......................General description....................
Page 3
Dentsply Sirona Table of contents Operating Instructions CEREC AC Electromagnetic compatibility ..............5.3.1 Electromagnetic emission .............. 5.3.2 Immunity to interference ............... 5.3.3 Working clearances ............... Installation and startup.................... Transport and unpacking ................Disposal of packaging materials ..............Scope of supply ...................
Page 4
Table of contents Dentsply Sirona Operating Instructions CEREC AC 8.1.3 Non-critical surfaces with no monitor ..........8.1.4 Trackball holder ................8.1.5 CEREC Omnicam ................8.1.5.1 General information ............8.1.5.2 Components of the Omnicam........8.1.5.3 Removing the mirror sleeve.......... 8.1.5.4 Refitting the mirror sleeve..........
Operating Instructions CEREC AC 1.1 Contact data Dear Customer, ® Thank you for your purchase of this CEREC AC unit from Dentsply Sirona. This device enables you to produce dental restorations, e.g. from ceramic material with a natural appearance (CEramic REConstruction).
2 General data Dentsply Sirona 2.1 Structure of the document Operating Instructions CEREC AC General data Please read this document completely and follow the instructions exactly. You should always keep it within reach. Original language of the present document: German.
Dentsply Sirona 2 General data Operating Instructions CEREC AC 2.2 Battery warranty 2.1.2 Formats and symbols used The formats and symbols used in this document have the following meaning: Prerequisite Requests you to do something. 1. First action step 2. Second action step ➢...
Storage battery pack recycling symbol (see "Disposal of the storage battery pack" [→ 75]) The CEREC AC acquisition unit may contain an RF transmitter in the form of a WLAN card or a separate wireless module. Radio approval for Australia/New Zealand Follow the operating instructions.
Page 9
Dentsply Sirona 2 General data Operating Instructions CEREC AC 2.3 Legend Symbols on the packaging Take note of the following symbols on the packaging: Protect from moisture Fragile; handle with care Temperature during storage and transport Relative humidity during storage and transport...
3 General description Dentsply Sirona 3.1 Certification Operating Instructions CEREC AC General description Certification CE mark This product bears the CE mark in accordance with the provisions of the Council Directive 93/42/EEC of June 14, 1993 concerning medical devices and their changes.
Operating Instructions CEREC AC 3.2 Intended use Intended use In connection with the grinding unit, the CEREC AC acquisition unit is used to manufacture dental restorations, e.g. from a natural-appearing ceramic material. The unit may be operated only by medically trained and qualified personnel.
CAUTION Note on the prevention, recognition, and elimination of unintended electromagnetic effects: The CEREC AC acquisition unit is Class B equipment (classified according to CISPR 11, EN 60601-1-2: 2007 based on IEC 60601-1-2:2007 and A1:2004). This system may be operated in a residential area provided that it is used under the responsibility of a medical specialist.
Dentsply Sirona 4 Safety Operating Instructions CEREC AC 4.1 Basic safety information NOTE Install only approved software To prevent interference with the runtime reliability of the program, only approved software may be installed. ➢ Use version ≥ CEREC software 4.0.4 or ➢...
In order to ensure product safety, this device may be operated only with original Dentsply Sirona accessories or third-party accessories expressly approved by Dentsply Sirona. The user is responsible for any damage resulting from the use of non-approved accessories. 4.1.7.1 Included accessories ●...
Dentsply Sirona 4 Safety Operating Instructions CEREC AC 4.2 Safety labels Safety labels Fuses NOTE Use ONLY fuses of the same type! 63 81 136 D3492 D3492.201.06.35.02 09.2019...
Page 16
4 Safety Dentsply Sirona 4.2 Safety labels Operating Instructions CEREC AC Plug connections of external interfaces CAUTION Additional devices connected to external interfaces must be tested according to the relevant standards, e.g.: EN 60601-1:1990 + A1:1993 + A2:1995 based on IEC 60601-1, EN...
Page 17
Dentsply Sirona 4 Safety Operating Instructions CEREC AC 4.2 Safety labels Heater plate CAUTION Risk of burns due to hot surface! ➢ Never touch the heater plate (A)! 63 81 136 D3492 D3492.201.06.35.02 09.2019...
4 Safety Dentsply Sirona 4.3 Electrostatic charge Operating Instructions CEREC AC Electrostatic charge 4.3.1 ESD warning labels ESD warning label CAUTION Risk of injury or damage to components from electrostatic discharge For electrical components labeled with an ESD warning label, observe the following instructions.
Dentsply Sirona 4 Safety Operating Instructions CEREC AC 4.3 Electrostatic charge 4.3.3 About the physics of electrostatic charges What is an electrostatic charge? An electrostatic charge is a voltage field on and in an object (e.g. a human body) which is protected against conductance to ground potential by a nonconductive layer (e.g.
In extreme cases, it will be impossible to establish a wireless connection at all. Dentsply Sirona has selected the best possible configuration for data communication via the wireless interface (CEREC Radio Device) or WLAN, which generally ensures perfect functioning of this connection.
Dentsply Sirona 4 Safety Operating Instructions CEREC AC 4.6 Integration in a network or connection to a modem Integration in a network or connection to a modem NOTE Observe the following installation regulations The following installation regulations apply to integration of the...
5 Technical information Dentsply Sirona 5.1 Technical description Operating Instructions CEREC AC Technical information Technical description CAD system for high-precision intraoral optical impressions ● High-resolution, heated oral camera (3D camera) with removable reflective sleeve (reflective sleeve sterilizable with hot air) ●...
Page 23
Dentsply Sirona 5 Technical information Operating Instructions CEREC AC 5.1 Technical description PC hardware Special PC with the following equipment: ® ● Processor: Intel ● Memory: 16 G B ● DVD-ROM/CD-R(W) ● Hard disk: 1x SATA HDD ● Network card: Ethernet 10/100/1000MBit/s ●...
5 Technical information Dentsply Sirona 5.2 Technical data Operating Instructions CEREC AC Technical data Type designation CEREC AC Acquisition unit Rated line voltage 100 - 240 VAC /50 - 60 Rated current 4.7 - 1.8 A Type of protection against electric shock...
Electromagnetic compatibility Observance of the following information is necessary to ensure safe operation regarding EMC aspects. CEREC AC complies with the requirements for electromagnetic compatibility (EMC) according to IEC 60601-1-2:2001 and A1:2004. CEREC AC is hereinafter referred to as "UNIT".
5 Technical information Dentsply Sirona 5.3 Electromagnetic compatibility Operating Instructions CEREC AC 5.3.2 Immunity to interference The UNIT is intended for operation in the electromagnetic environment specified below. The customer or user of the UNIT should make sure that it is used in such an environment.
5 Technical information Dentsply Sirona 5.3 Electromagnetic compatibility Operating Instructions CEREC AC 5.3.3 Working clearances Recommended working clearances The UNIT is intended for operation in an electromagnetic environment, between portable and mobile RF where radiated RF interference is checked. The customer or the user of...
6.1 Transport and unpacking Installation and startup Transport and unpacking All products from Dentsply Sirona are carefully checked prior to shipment. Please perform an incoming inspection immediately after delivery. 1. Check the delivery note to ensure that the consignment is complete.
6 Installation and startup Dentsply Sirona 6.4 Initial startup Operating Instructions CEREC AC Initial startup 6.4.1 Controls and functional elements Overview of the front panel Monitor ON/OFF switch Center trackball button Membrane keyboard Left trackball button CEREC Omnicam Trackball Heater plate...
Page 31
Dentsply Sirona 6 Installation and startup Operating Instructions CEREC AC 6.4 Initial startup Operating state LED ON button Components of the Omnicam Press detent to release Camera windows Mirror sleeve Calibration set Sapphire glass (coated) NOTE CEREC Omnicam is calibrated The CEREC Omnicam is calibrated ex works (see "Calibrating...
Page 32
6 Installation and startup Dentsply Sirona 6.4 Initial startup Operating Instructions CEREC AC Overview of rear side Fuses Power connection Main switch USB port I = ON, 0 = OFF 63 81 136 D3492 D3492.201.06.35.02 09.2019...
Dentsply Sirona 6 Installation and startup Operating Instructions CEREC AC 6.4 Initial startup 6.4.2 Operating state LED Operating state LED ON button LED not lit: Acquisition unit is switched off at main switch. LED lights up yel- Acquisition unit is switched on at main switch,...
1. Connect the unit to the line voltage with the power cord. 2. Carefully insert the connector of the CEREC Omnicam cable into the coupling on the CEREC AC, watching out for the guide nose. 3. Check the plug connections of the power supply and the camera.
Dentsply Sirona 6 Installation and startup Operating Instructions CEREC AC 6.4 Initial startup 6.4.4 Insert battery (optional) Bottom door Battery cover Storage battery Battery connector 1. Open the lower door on the back panel. NOTE Open with coin. Use a coin to open the latch. Turn counterclockwise.
Ä The unit is dry and can be put into operation. CAUTION Use only the supplied power cord Use only the power cord supplied by Dentsply Sirona to connect the acquisition unit to the power supply. If the acquisition unit is switched on at the main switch, it can be activated with the ON button.
Dentsply Sirona 6 Installation and startup Operating Instructions CEREC AC 6.4 Initial startup NOTE Possible data loss and PC malfunction: Switching the acquisition unit off at the ON button during operation may cause data loss and PC malfunctions. ➢ Always switch the unit off as described in the chapter "Switching the units off".
At least every three months the CEREC AC acquisition unit must be connected to the mains supply to charge the storage batteries.
Page 39
Dentsply Sirona 6 Installation and startup Operating Instructions CEREC AC 6.5 Battery-backed operation (optional) The color of the symbol has the following meaning: ● Green = line voltage present, fan functioning, temperature OK. ● Yellow = Unit running in battery-powered mode, all other operating parameters OK.
Page 40
6 Installation and startup Dentsply Sirona 6.5 Battery-backed operation (optional) Operating Instructions CEREC AC Monitoring window Explanation When the battery charge is almost depleted, the shut- down window opens. The operating system is then shut down after 30s and the PC can then be switched off.
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.1 Camera warm-up time Operation Camera warm-up time When switching on the system, the camera needs to warm up for 15 - 20 minutes. If the coated sapphire glass of the Omnicam is not sufficiently warm, it may steam up during the acquisition.
7 Operation Dentsply Sirona 7.3 Taking acquisitions with the CEREC Omnicam Operating Instructions CEREC AC Taking acquisitions with the CEREC Omnicam CAUTION Hot surface! The coated sapphire layer of the CEREC Omnicam is preheated in the camera cradle. When removing the CEREC Omnicam from its cradle, the surface temperature of the mirror sleeve can be up to 51°C.
Page 43
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.3 Taking acquisitions with the CEREC Omnicam WARNING Risk of injury for those diagnosed with epilepsy For persons who have been diagnosed with epilepsy, there is a risk of epileptic shock through the flashing light of the CEREC Omnicam scanner.
7 Operation Dentsply Sirona 7.4 Directing the camera Operating Instructions CEREC AC Directing the camera CAUTION After each use Prepare the camera once again after each patient. ➢ Follow the instructions in the "CEREC Omnicam [→ 54]" section in order to avoid cross-contamination between patients.
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.4 Directing the camera 7.4.1 Occlusal scan Important: Ensure that the distance between the coated sapphire glass of the CEREC Omnicam and the scanned surface is observed. The distance must be between 0 - 1 5 mm (ideally: 5 mm). The camera does not rest on the teeth or the gums.
7 Operation Dentsply Sirona 7.4 Directing the camera Operating Instructions CEREC AC 7.4.3 Lingual scan ü The CEREC Omnicam is on the tooth that is positioned next to the preparation in the distal direction. 1. Rotate the CEREC Omnicam from 90° in the buccal direction to around 45°...
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.4 Directing the camera 7.4.5 Buccal registration A buccal registration can be used to establish contact with the antagonist. ü The jaw with the preparation is scanned. 1. Scan the occlusal, buccal and lingual view of the antagonist (see the section “Occlusal scan ...
Page 48
7 Operation Dentsply Sirona 7.4 Directing the camera Operating Instructions CEREC AC Completing the scanning process 1. Start as indicated above, on the occlusal surface of the right terminal tooth, and scan it occlusally. Tilt the camera by 45° in a palatinal direction (oral) and guide it from the distal to the mesial.
Page 49
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.4 Directing the camera The following scan sequence is implemented for the opposite second (third) quadrant: 1. Start by placing the device on the occlusal surface of a premolar, that has already been scanned, and guide the camera palatally (orally) at a mesial tilt of up to 90°...
7 Operation Dentsply Sirona 7.4 Directing the camera Operating Instructions CEREC AC ● When performing this activity, be careful not to accidentally cut out any areas that e.g. are located behind the model or are otherwise cut away from the line.
Dentsply Sirona 7 Operation Operating Instructions CEREC AC 7.5 Software for the CEREC Omnicam Software for the CEREC Omnicam Refer to the Operator's Manual for more information on using the CEREC SW and the CEREC Premium SW. You can find additional information on setting the CEREC Omnicam in the "Adjusting the CEREC Omnicam"...
Some countries have legal regulations which require regular safety inspections of electrical devices or systems by the operator. Dentsply Sirona would like to draw your attention to the fact that a so- called "retest" (repeat test) must be carried out for the CEREC AC acquisition unit at least every three years.
"Cleaning agents and disinfectants [→ 52]" section to disinfect the non-critical contact surfaces of the CEREC AC, such as the camera holder, keyboard, and trackball. 2. Dispose of the absorbent gauze. Please ensure that no colored cloths are used for this as these can result in discoloration of the surfaces, e.g.
8 Maintenance Dentsply Sirona 8.1 Care, cleaning, disinfection, and sterilization Operating Instructions CEREC AC 8.1.4 Trackball holder 1. Rotate the cover ring counterclockwise and remove it. 2. Clean inner surface of cover ring (A) with ethanol (commercially available cleaning alcohol).
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.1 Care, cleaning, disinfection, and sterilization 8.1.5.1 General information The CEREC Omnicam is a very sensitive optical device and must therefore be handled with the utmost care. Protect the coated sapphire glass and the camera window against scratches and clean them with a lint-free cloth and ethanol (commercially available cleaning alcohol) if any haze is noted during the acquisition.
8 Maintenance Dentsply Sirona 8.1 Care, cleaning, disinfection, and sterilization Operating Instructions CEREC AC 8.1.5.4 Refitting the mirror sleeve ➢ Carefully refit the mirror sleeve until it locks in place. NOTE There is a risk of damaging the camera window or the coated sapphire glass if the mirror sleeve is not pushed straight toward the front.
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.1 Care, cleaning, disinfection, and sterilization 8.1.5.7 High-level disinfection of the mirror sleeve NOTE The hot air sterilization and high-level disinfection must not be combined. The complete process for high-level disinfection (HLD) is as follows –...
Page 58
8 Maintenance Dentsply Sirona 8.1 Care, cleaning, disinfection, and sterilization Operating Instructions CEREC AC 6. Push the plug completely into the metal bracket. 7. Press the mirror sleeve onto the plug while holding the metal bracket firmly in place in order to ensure that no particle contamination or fluids penetrate the inside of the mirror sleeve.
Page 59
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.1 Care, cleaning, disinfection, and sterilization 9. Insert the metal bracket with the metal sleeve. 10. Place the cover on the container and leave the mirror sleeve in the ® disinfectant for at least 12 minutes (CIDEX OPA).
Page 60
8 Maintenance Dentsply Sirona 8.1 Care, cleaning, disinfection, and sterilization Operating Instructions CEREC AC 11. Remove the cover and take the bracket with the mirror sleeve out of the container. 12. Carefully rinse the mirror sleeve with tap water for at least 30 seconds while holding it with the bracket.
Page 61
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.1 Care, cleaning, disinfection, and sterilization 17. Dry the entire outer surface of the mirror sleeve as well as the inner section using a soft lint-free cloth. Ensure that no fluid is able to penetrate the inside of the mirror sleeve.
8 Maintenance Dentsply Sirona 8.1 Care, cleaning, disinfection, and sterilization Operating Instructions CEREC AC 8.1.5.8 Hot air sterilization of the mirror sleeve NOTE Hot air sterilization and high-level disinfection must not be combined. The process for hot air sterilization is as follows: 1.
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.1 Care, cleaning, disinfection, and sterilization 8.1.5.9 Use of CEREC Omnicam disposable sleeves The CEREC Omnicam can be operated with disposable plastic sleeves in order to ensure maximum infection control. The sleeves are available using order number 66 32 264.
8 Maintenance Dentsply Sirona 8.2 Calibrating CEREC Omnicam Operating Instructions CEREC AC Calibrating CEREC Omnicam The measurement procedure used by the system requires the use of a calibrated CEREC Omnicam. The CEREC Omnicam is factory- calibrated. Then calibrate the CEREC Omnicam after every reinstallation and after every transport.
Page 65
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.2 Calibrating CEREC Omnicam Calibrate the camera 1. Remove the protective cap from the calibration set. 2. Mount the calibration set on the tip of the camera until it locks into place.
Page 66
8 Maintenance Dentsply Sirona 8.2 Calibrating CEREC Omnicam Operating Instructions CEREC AC Measuring the position of the exit window 1. Mount the bottom side of the calibration set to the tip of the camera. 2. Click on the "OK" button.
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.3 Color calibration Color calibration General information NOTE Faulty color analysis The color analysis can be negatively impacted due to strong light incidence and it can lead to varying results. ➢ Set the model CEREC Omnicam up so that it is not located directly in the beam path of an extreme light source (e.g., the...
Page 68
8 Maintenance Dentsply Sirona 8.3 Color calibration Operating Instructions CEREC AC Carry out a color calibration also after changing a mirror sleeve. Heavily scratched mirror sleeves may not be used for a color analysis. Storing a color-calibration set The color-calibration set must be stored in its packaging in a dry place which is protected from light.
Page 69
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.3 Color calibration Color-calibrating the camera 1. Make sure that the CEREC Omnicam is clean, disinfected and dry. 2. Remove the color-calibration set from the packaging. 3. Use the CEREC Omnicam to scan the QR code on the underside of your color-calibration set.
Page 70
8 Maintenance Dentsply Sirona 8.3 Color calibration Operating Instructions CEREC AC Replacing the color calibration set Please note that the color calibration set ● can only be used with CEREC SW software ≥ 4.5 or Sirona Connect SW ≥ 4.5 or CEREC Premium SW ≥ 4.5.
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.4 Replacing the main fuse Replacing the main fuse WARNING Electric shock Disconnect the power plug at the unit end before replacing the fuses. NOTE Fuse type Use only fuses of the same type in the fuse module!
8 Maintenance Dentsply Sirona 8.5 Charge battery (optional) Operating Instructions CEREC AC Charge battery (optional) NOTE Reduced buffer cycles After around 1000 buffer cycles the capacity of the battery fades due to the nature of the battery technology used. If the buffer times are too short, you should replace the battery.
Dentsply Sirona 8 Maintenance Operating Instructions CEREC AC 8.6 Replace battery (optional) Replace battery (optional) Bottom door Battery cover Storage battery Battery connector 1. Open the lower door on the back panel. NOTE Open with coin. Use a coin to open the latch. Turn counterclockwise.
9 Disposal Dentsply Sirona Operating Instructions CEREC AC Disposal In accordance with Directive 2012/19/EU and national disposal regulations regarding old electrical and electronic devices, please be advised that such items must be disposed of in a special way within the European Union (EU).
Dentsply Sirona 9 Disposal Operating Instructions CEREC AC 9.1 Disposal of the storage battery pack Disposal of the storage battery pack The storage battery pack must be subjected to recycling if it becomes defective or reaches the end of its service life. For country-specific information on disposal, contact your local dental dealers.
10 PC Diagnostic Tool Dentsply Sirona 10.1 Start diagnostic tool Operating Instructions CEREC AC PC Diagnostic Tool Start diagnostic tool 10.1 Test Suitable for Customer Diagnostics Suitable for the user, in order to check the PC components. Technician Diagnostics Suitable for the technician, in order to check the PC components.
Dentsply Sirona 10 PC Diagnostic Tool Operating Instructions CEREC AC 10.2 Test procedure Test procedure 10.2 10.2.1 Customer Diagnostics ü You have started the "Customer Diagnostics" test and the system configuration is displayed. 1. Using the information in the system configuration, check whether the system corresponds to the default settings.
Page 78
10 PC Diagnostic Tool Dentsply Sirona 10.2 Test procedure Operating Instructions CEREC AC Ä The result, i.e. "Pass" or "Fail", appears at the end of the test (see sections entitled "Test result: Pass" or "Test result: Fail"). 3. On completion of the test, press any key to go on to the test dialog.
Dentsply Sirona 10 PC Diagnostic Tool Operating Instructions CEREC AC 10.2 Test procedure 10.2.2 Technician Diagnostics ü You have started the "Technician Diagnostics" test and the system configuration is displayed. 1. Using the information in the system configuration, check whether the system corresponds to the default settings.
Page 80
10 PC Diagnostic Tool Dentsply Sirona 10.2 Test procedure Operating Instructions CEREC AC 3. On completion of the test, press any key to go on to the test dialog. Tip: You can scroll to the individual test steps using the arrow keys.
Dentsply Sirona 10 PC Diagnostic Tool Operating Instructions CEREC AC 10.2 Test procedure 10.2.3 Sirona Windows Diagnostics General The "Sirona Windows Diagnostics" test loads the PC-specific components simultaneously over a long period of time. This period of time is determined by the user.
10 PC Diagnostic Tool Dentsply Sirona 10.3 Troubleshooting Operating Instructions CEREC AC Test result: Pass No errors were found on the PC-specific hardware. Replacing the PC component or the PC is not advisable. Test result: Fail An error was found on the PC-specific hardware. Replacing the PC component or the PC may be required.
Dentsply Sirona 10 PC Diagnostic Tool Operating Instructions CEREC AC 10.3 Troubleshooting 10.3.1 Customer Diagnostics & Technician Diagnostics Test Test description / condition Action if problems occur Display Script Control command without a test n.a. function Activity is rotating cursor...
Page 84
Test description / condition Action if problems occur Test WDC___TYP HDD___Short A range of destruction-free tests on 1. For the CEREC AC check the Self-Test the hard drives installed in a system setting of the ASM1061 Storage are conducted with these functions.
Page 85
Dentsply Sirona 10 PC Diagnostic Tool Operating Instructions CEREC AC 10.3 Troubleshooting 63 81 136 D3492 D3492.201.06.35.02 09.2019...
10 PC Diagnostic Tool Dentsply Sirona 10.3 Troubleshooting Operating Instructions CEREC AC 10.3.2 Sirona Windows Diagnostics Test Test Description Action if problems occur Processor(s) Continuous load and inspection of pro- ➢ Replace the PC. cessor cores Motherboard testing Continuous load and inspection of the ➢...
Dentsply Sirona 11 Appendix Operating Instructions CEREC AC 11.1 DVD playback Appendix DVD playback 11.1 DVD videos can be played back on the acquisition unit via "Windows Media Center" . ➢ Start the program via the corresponding icon or via "Start" / "All Programs"...
11 Appendix Dentsply Sirona 11.3 Seal on PC slide-in module Operating Instructions CEREC AC Seal on PC slide-in module 11.3 NOTE If the seal is broken, all warranty claims regarding the PC slide- module automatically expire. The PC slide-in module may be opened only by an authorized dental technician.