Dentsply Sirona
Operating Instructions CEREC AC
63 81 136 D3492
D3492.201.06.35.02 09.2019
10.2.3
Sirona Windows Diagnostics
General
The "Sirona Windows Diagnostics" test loads the PC-specific
components simultaneously over a long period of time. This period of
time is determined by the user.
As a result of this load
● the temperature in the PC is significantly increased compared with
normal operation.
A temperature malfunction or any existing faults are thereby
detected.
● Thanks to the temporal, unlimited test phase, sporadically occurring
faults are more likely to be detected.
Tip: Only conduct the test if at least one of the "Customer
Diagnostics" or "Technician Diagnostics" tests has been
completed with a "pass" and without errors.
Performing the test
Tip: Allow the "Sirona Windows Diagnostics" test to run for at
least 1 hour. For optimum results, allow the test to run overnight.
ü You have started the "Sirona Windows Diagnostics" test
and Windows starts in the test environment. The "Sirona
Windows Diagnostics" test starts automatically.
➢ Check the result in the "Windows Stress Test" window.
Tip: You may have to rearrange the windows to be able to see the
"Windows Stress Test" window.
10 PC Diagnostic Tool
10.2 Test procedure
81