  • Page 1 12.2018 New as of: Intego / Intego Pro Intego Ambidextrous / Intego Pro Ambidextrous Installation requirements English...
  • Page 2: Table Of Contents

    On-site installation ....................Substrate, floor..................... 3.1.1 Load-bearing capacity of the floor..........3.1.2 Stability ..................3.1.2.1 With Intego and Intego pro ........... 3.1.2.2 With Intego Ambidextrous and Intego pro Ambidextrous..............Requirements of the supply media .............. 3.2.1 Requirements of the water supply ..........
  • Page 3 Distances in the Intego pro treatment room with Heliodent Plus unit model ..................4.2.7 Side view of Intego pro with Heliodent Plus unit model ....Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 4.3.1 Distances in the Intego Ambidextrous, Intego pro Ambidextrous treatment room................
  • Page 4: Dentsply Sirona

    Table of contents Dentsply Sirona Installation requirements Intego Checklist ......................... Installation site ..................... Construction requirements................IT hardware....................Network......................Data processing ................... 64 57 092 D3543 D3543.021.01.09.02    12.2018...
  • Page 5: General Information

    General information Notes on the installation prerequisites This document describes the installation prerequisites for all versions of the Intego treatment center. It contains the following information: ● Required information for practice planning. ● Information for the installer and operator regarding the necessary quality of the air and water supply media.
  • Page 6: Structure Of The Document

    1 General information Dentsply Sirona 1.2 Structure of the document Installation requirements Intego Structure of the document 1.2.1 Identification of the danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in these operating instructions.
  • Page 7: Safety Information

    For reasons of product safety, this product may be operated only with original Dentsply Sirona parts or third-party parts expressly approved by Dentsply Sirona. In the event of changes which were not foreseen, Dentsply Sirona is not liable for resulting damages.
  • Page 8: On-Site Installation

    3 On-site installation Dentsply Sirona 3.1 Substrate, floor Installation requirements Intego On-site installation Substrate, floor Unevenness The floor must be level and horizontal in accordance with DIN 18 202. The compensating plates (A) in the accessory pack can be used for slight unevenness in the floor.
  • Page 9: Stability

    3.1 Substrate, floor 3.1.2 Stability 3.1.2.1 With Intego and Intego pro With a concrete floor ● Use a 12mm dia. masonry drill to drill the holes. ● The depth of the holes depends on the condition of the floor. For concrete floor without screed...
  • Page 10: With Intego Ambidextrous And Intego Pro Ambidextrous

    3.1 Substrate, floor Installation requirements Intego 3.1.2.2 With Intego Ambidextrous and Intego pro Ambidextrous With a concrete floor ● Use a 12mm dia. masonry drill to drill the holes. ● The depth of the holes depends on the condition of the floor.
  • Page 11: Dentsply Sirona

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.1 Substrate, floor With a wooden floor ● Use a 7 mm dia. wood drill to drill the holes. ● Hole depth is: For wooden floor (D): Hole depth 120 mm (G) 6 or 8 screws 110 mm long (E)
  • Page 12: Requirements Of The Supply Media

    3 On-site installation Dentsply Sirona 3.2 Requirements of the supply media Installation requirements Intego Requirements of the supply media * = For use with an Air Venturi air jet pump Suction machine Compressed air (free from oil) The compressor must be able to draw in air in an efficient, hygienic manner.
  • Page 13: Requirements Of The Water Supply

    With In- tego, the optional fresh water bottle can be used as a water container, as can the empty disinfec- tant tank with Intego Pro. Sampling and the colony count must be performed by a competent laboratory.
  • Page 14: Connection To The Public Drinking Water System

    Connection to the public drinking water system Treatment center isolated from the public drinking water supply The Intego Pro treatment center, if it is equipped with a disinfection system, complies with the requirements of EN 1717 (free discharge with an isolation distance ≥ 20 mm) and the DVGW German Gas and Water Association).
  • Page 15: Installation Of The Water Supply On The Building Side

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.2 Requirements of the supply media 3.2.1.3 Installation of the water supply on the building side ● Carry out the installation in accordance with the national installation requirements (e.g. EN 1717). ● Connect the treatment center to the cold water supply.
  • Page 16: Requirements Of The Air Supply

    3 On-site installation Dentsply Sirona 3.2 Requirements of the supply media Installation requirements Intego 3.2.2 Requirements of the air supply The air supply is required to drive the turbines, cool the drill drives, for the cooling spray and to control the treatment center.
  • Page 17: Requirements Of The Suction Machine

    – 11 mm: Spray aspirator ● INTEGO: Filter mesh size 1.5 x 3.0 mm ● INTEGO pro: Filter mesh size 1.3 x 1.3 mm ● Sirona recommends using cannulae with a bypass in order to prevent return flow in adhered cannulas.
  • Page 18: Typical Pressure Loss In The Suction System

    3 On-site installation Dentsply Sirona 3.2 Requirements of the supply media Installation requirements Intego 3.2.3.1 Typical pressure loss in the suction system Suction flow of large suction hose red (○): Only large suction device black (◊): Saliva ejector in parallel 3.2.4...
  • Page 19: Above-Floor Installation Of Supply Lines

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.3 Above-floor installation of supply lines Above-floor installation of supply lines The supply lines can be installed above the floor (above-floor installation) or through the floor (underfloor installation). For the installation of the supply lines through the floor, see "Underfloor installation of supply lines" ...
  • Page 20: Dentsply Sirona

    3 On-site installation Dentsply Sirona 3.3 Above-floor installation of supply lines Installation requirements Intego In the case of re-ordering for a retrofit ● For connection from the wall, the above-floor installation kit and a diaphragm are required: – Above-floor installation kit (D) Order No.: 64 43 746 and –...
  • Page 21: Dentsply Sirona

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.3 Above-floor installation of supply lines Suction line DN40 HT-PP ISO 8283-3 (polypropylene, inner diameter approx. 36.5 mm) Compressed air supply Pipe 10x1 mm, corner valve outlet 3/8" Water supply Pipe 10x1 mm, corner valve outlet 3/8"...
  • Page 22: Underfloor Installation Of Supply Lines

    3 On-site installation Dentsply Sirona 3.4 Underfloor installation of supply lines Installation requirements Intego Underfloor installation of supply lines 3.4.1 Installation template We recommend that you order the installation template (REF 33 15 830) from Sirona for laying the pipe ends in the installation field.
  • Page 23: Dentsply Sirona

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.4 Underfloor installation of supply lines Pipe no. Cable Symbol Laying the installation template Water supply Pipe 10x1 mm, corner valve outlet 3/8" Compressed air supply Pipe 10x1 mm, corner valve outlet 3/8" Suction line DN40 HT-PP ISO 8283-3...
  • Page 24: Installation Of The Supply Lines In The Termination Panel

    3 On-site installation Dentsply Sirona 3.4 Underfloor installation of supply lines Installation requirements Intego 3.4.2 Installation of the supply lines in the termination panel ü An installation template is available or was prepared. 1. Check the position of the supply lines against the installation template as per the practice blueprint.
  • Page 25: Cleaning The Air And Water Pipes

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.5 Cleaning the air and water pipes Cleaning the air and water pipes NOTE Chips and other foreign materials could be flushed and/or blown into the treatment center. Metal chips can cause malfunctions of the pneumatic components.
  • Page 26: Potential Equalization

    3 On-site installation Dentsply Sirona 3.6 Potential equalization Installation requirements Intego Potential equalization The treatment center does not require potential equalization The treatment center, monitor, PC and devices connected to the external device connection have the same potential as a result of the wiring of the treatment center.
  • Page 27: Underfloor Installation Of The Pc Connections

    Dentsply Sirona 3 On-site installation Installation requirements Intego 3.7 Underfloor installation of the PC connections Underfloor installation of the PC connections Depending on the prevailing local conditions, the existing cable set can be installed in the cable duct of an underfloor installation by an installer.
  • Page 28: Dentsply Sirona

    3 On-site installation Dentsply Sirona 3.7 Underfloor installation of the PC connections Installation requirements Intego ➢ Pull the USB , Ethernet, HDMI cables and protective ground wire from the treatment center through the cable duct to the location of the PCs C.
  • Page 29: Dimensions, Technical Data

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.1 Intego dimensions, scale 1:20 Dimensions, technical data Intego dimensions, scale 1:20 4.1.1 Distances in the Intego treatment room 1400 1100 55 1/8” 43 5/16” 2250 88 9/16” 7 7/8” 19 5/8”...
  • Page 30: Intego Side View

    4 Dimensions, technical data Dentsply Sirona 4.1 Intego dimensions, scale 1:20 Installation requirements Intego 4.1.2 Intego side view IMPORTANT Recommended room height ≥ 2220 mm Dimensions at the Compact water unit Monitor on lamp support tube Height of dentist element TS or CS...
  • Page 31: Top View Of Intego With Dentist Element Cs

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.1 Intego dimensions, scale 1:20 4.1.3 Top view of Intego with dentist element CS 1240 48 7/8” 75° 30° 7 7/8” 14 3/4” 30° 240° 30° 33 7/8” max. 7 7/8”...
  • Page 32: Top View Of Intego With Dentist Element Ts

    4 Dimensions, technical data Dentsply Sirona 4.1 Intego dimensions, scale 1:20 Installation requirements Intego 4.1.4 Top view of Intego with dentist element TS 1240 48 7/8” 75° 30° 7 7/8” 14 3/4” 30° 30° 240° 33 7/8” max. 7 7/8”...
  • Page 33: Top View Of Intego With Options

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.1 Intego dimensions, scale 1:20 4.1.5 Top view of Intego with options TS dentist element CS dentist element 64 57 092 D3543 D3543.021.01.09.02    12.2018...
  • Page 34: Dentsply Sirona

    4 Dimensions, technical data Dentsply Sirona 4.1 Intego dimensions, scale 1:20 Installation requirements Intego LEDlight Plus LEDview Plus LEDview Monitor Comfort assistant element...
  • Page 35: Distances In The Intego Treatment Room With Heliodent Plus Unit Model

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.1 Intego dimensions, scale 1:20 4.1.6 Distances in the Intego treatment room with Heliodent Plus unit model Recommended distances from cabinet or wall. Center of the floor cut-out/installation area IMPORTANT! The lamp installed here and the dentist element with/without a tray and the Heliodent Plus have a swivel range which exceeds the specified distances.
  • Page 36: Side View Of Intego With Heliodent Plus Unit Model

    Side view of Intego with Heliodent Plus unit model Recommended installation height for wall adapter: 1110 mm (43 3/4“) Cable bushing for radiation cable The radiation cable between Intego and the wall adapter is supplied (12.5 mm outer diameter, max. cable length 10 me- ters (393”). CAUTION The Heliodent Plus radiation cable must not be laid together with USB or HDMI cables.
  • Page 37: Intego Pro Dimensions, Scale 1:20

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.2 Intego pro dimensions, scale 1:20 Intego pro dimensions, scale 1:20 4.2.1 Distances in the Intego pro treatment room 1400 1100 55 1/8” 43 5/16” 2250 88 9/16” 7 7/8” 19 5/8”...
  • Page 38: Intego Pro Side View

    4 Dimensions, technical data Dentsply Sirona 4.2 Intego pro dimensions, scale 1:20 Installation requirements Intego 4.2.2 Intego pro side view IMPORTANT Recommended room height ≥ 2220 mm Dimensions at the Comfort water unit (height and swivel range) Monitor on lamp support tube...
  • Page 39: Top View Of Intego Pro With Dentist Element Cs

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.2 Intego pro dimensions, scale 1:20 4.2.3 Top view of Intego pro with dentist element CS 2140 84 1/4” 14° 110° 42° 30° 7 7/8” 90° 240° 14 3/4” 1220 40”...
  • Page 40: Top View Of Intego Pro With Dentist Element Ts

    4 Dimensions, technical data Dentsply Sirona 4.2 Intego pro dimensions, scale 1:20 Installation requirements Intego 4.2.4 Top view of Intego pro with dentist element TS 2140 84 1/4” 14° 110° 42° 30° 7 7/8” 90° 240° 14 3/4” 1220 40”...
  • Page 41: Top View Of Intego Pro With Options

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.2 Intego pro dimensions, scale 1:20 4.2.5 Top view of Intego pro with options TS dentist element CS dentist element 64 57 092 D3543 D3543.021.01.09.02    12.2018...
  • Page 42: Dentsply Sirona

    4 Dimensions, technical data Dentsply Sirona 4.2 Intego pro dimensions, scale 1:20 Installation requirements Intego LEDlight Plus LEDview Plus LEDview Monitor...
  • Page 43: Distances In The Intego Pro Treatment Room With Heliodent Plus Unit Model

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.2 Intego pro dimensions, scale 1:20 4.2.6 Distances in the Intego pro treatment room with Heliodent Plus unit model Recommended distances from cabinet or wall. Center of the floor cut-out/installation area IMPORTANT!
  • Page 44: Side View Of Intego Pro With Heliodent Plus Unit Model

    Dentsply Sirona 4.2 Intego pro dimensions, scale 1:20 Installation requirements Intego 4.2.7 Side view of Intego pro with Heliodent Plus unit model Recommended installation height for wall adapter: 1110 mm (43 3/4“) Cable bushing for radiation cable The radiation cable between Intego and the wall adapter is supplied (12.5 mm outer diameter, max.
  • Page 45: Dimensions For Intego Ambidextrous, Intego Pro Ambidextrous, Scale 1:20

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 4.3.1 Distances in the Intego Ambidextrous, Intego pro Ambidextrous treatment room Recommended distances from cabinet or wall.
  • Page 46 4 Dimensions, technical data Dentsply Sirona 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 Installation requirements Intego Dentist element TS or CS IMPORTANT! The minimum distance of the rear edge of the chair (with cladding) to the wall or cabinets must be complied with, other- wise the water unit cannot be fully swiveled round.
  • Page 47: Side View Of Intego Ambidextrous, Intego Pro Ambidextrous

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 4.3.2 Side view of Intego Ambidextrous, Intego pro Ambidextrous IMPORTANT Recommended room height ≥ 2220 mm Dimensions at the Compact water unit...
  • Page 48: Top View Of Intego Ambidextrous, Intego Pro Ambidextrous With Dentist Element Cs

    4 Dimensions, technical data Dentsply Sirona 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 Installation requirements Intego 4.3.3 Top view of Intego Ambidextrous, Intego pro Ambidextrous with dentist element CS Head support: Length of treatment center with patient height of 176 ...
  • Page 49: Top View Of Intego Ambidextrous, Intego Pro Ambidextrous With Dentist Element Ts

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 4.3.4 Top view of Intego Ambidextrous, Intego pro Ambidextrous with dentist element TS Head support: Length of treatment center with patient height of 176 ...
  • Page 50: Top View Of Intego Ambidextrous, Intego Pro Ambidextrous With Options

    4 Dimensions, technical data Dentsply Sirona 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 Installation requirements Intego 4.3.5 Top view of Intego Ambidextrous, Intego pro Ambidextrous with options TS dentist element CS dentist element...
  • Page 51: Dentsply Sirona

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.3 Dimensions for Intego Ambidextrous, Intego pro Ambidextrous, scale 1:20 LEDlight Plus LEDview Plus LEDview Monitor 64 57 092 D3543 D3543.021.01.09.02    12.2018...
  • Page 52: Mounting Plates

    Adapter plate Adapter plates are available for replacement of one of the following dental treatment centers for a right-handed person with a Intego / Intego Pro treatment center: ● C2, C3, C4, C6, C8 (in the case of C4, year of manufacture 1999-2001, a new drill hole must be drilled in the area of the water unit (C) .)
  • Page 53: Dentsply Sirona

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.4 Mounting plates REF 65 93 433 adapter plate IntegoAmbidextrous cpl.: 64 57 092 D3543 D3543.021.01.09.02    12.2018...
  • Page 54: Dentsply Sirona

    4 Dimensions, technical data Dentsply Sirona 4.4 Mounting plates Installation requirements Intego 1/2" 7 7/8" 5" 16 3/8" 8 5/8" 9 7/8" 35 3/8" 1224 48 2/11"...
  • Page 55: Dentsply Sirona

    D on the floor using two screws. Demo chair plate thickness: 10 mm REF 64 46 061 Intego / Intego Pro demo chair plate INTEGO Ambidextrous / INTEGO pro Ambidextrous demo chair plate For floors which do not permit permanent connection of the unit (e.g.
  • Page 56: Dentsply Sirona

    4 Dimensions, technical data Dentsply Sirona 4.4 Mounting plates Installation requirements Intego Overall thickness of demo chair plate: 22 mm REF 65 93 383 demo chair plate IntegoAmbidextrous (2-piece) and REF 65 93 433 adapter plate IntegoAmbidextrous cpl.
  • Page 57: Information On Planning For The Practice

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.5 Information on planning for the practice Information on planning for the practice The following file(s) for practice planning are available for download in the dealer area of the Sirona website under DOWNLOADS => CAAD files: ●...
  • Page 58: Technical Data

    4 Dimensions, technical data Dentsply Sirona 4.6 Technical data Installation requirements Intego Technical data Model designation: Intego / Intego Pro Power connection: 100 – 240 V AC ± 10% 50/60 Hz Rated current: 3.3 A – 1.5 A at 100 – 240 V also max. 6 A for external devices...
  • Page 59: Operating, Transport And Storage Conditions

    Dentsply Sirona 4 Dimensions, technical data Installation requirements Intego 4.6 Technical data 4.6.1 Operating, transport and storage conditions Mode of operation Continuous operation with intermittent loading corresponding to the dental mode of working. Drive motors for chair operation: intermittent use, max. 2 minutes on and 18 minutes off Permanently connected unit.
  • Page 60: Weight And Packaging

    Dentsply Sirona 4.6 Technical data Installation requirements Intego 4.6.2 Weight and packaging Dimensions of the packaging Weight (with packaging and ac- cessories/without packaging): Intego CS dentist element: 120 cm x 80 cm x 92 cm 37 kg / 24.5 kg Intego TS dentist element: 120 cm x 80 cm x 71 cm 36 kg / 24 kg Comfort assistant element: 87 cm x 31 cm x 82 cm 10.4 kg / 6 kg...
  • Page 61: Standards/Approvals

    “Connection to the public drinking water supply”  [→ 14] Original language of this document: German ANVISA registration number: 80745400024 Intego / Intego Pro bear the CE marking in accordance with the provisions of Council Directive 93/42/EEC of June 14, 1993 concerning medical devices.
  • Page 62: Dentsply Sirona

    4 Dimensions, technical data Dentsply Sirona 4.7 Standards/Approvals Installation requirements Intego When equipped with a disinfection system or fresh water bottle without switchover to the public drinking water supply, the treatment center complies with the technical rules and requirements on safety and hygiene for connection to the public drinking water supply.
  • Page 63: Electromagnetic Compatibility

    5.1 Accessories Electromagnetic compatibility Observance of the following information is necessary to ensure safe operation regarding EMC aspects. Intego complies with the requirements for electromagnetic compatibility (EMC) according to IEC 60601-1-2:2014 Intego is hereinafter referred to as "UNIT". Accessories Connecting the PC The required interface cables can be ordered from Sirona.
  • Page 64: Electromagnetic Emission

    5 Electromagnetic compatibility Dentsply Sirona 5.2 Electromagnetic emission Installation requirements Intego Accessories for EMC measurement The EMC measurements were performed with the following PC: PC as peripheral device for checking Fujitsu the interfaces with: ESPRIMO P710 E90+ PC equipment: Processor Intel Core i5 3470;...
  • Page 65: Immunity To Interference

    Dentsply Sirona 5 Electromagnetic compatibility Installation requirements Intego 5.3 Immunity to interference Immunity to interference The UNIT is intended for operation in the electromagnetic environment specified below. The customer or user of the UNIT should make sure that it is used in such an environment.
  • Page 66 5 Electromagnetic compatibility Dentsply Sirona 5.3 Immunity to interference Installation requirements Intego Interference immunity IEC 60601-1-2 test Compliance level Electromagnetic environment - tests level guidelines Conducted RF interfer- 3 V d= [1.2] √P ence 150 kHz to 80 MHz IEC 61000-4-6 6 V...
  • Page 67 Dentsply Sirona 5 Electromagnetic compatibility Installation requirements Intego 5.3 Immunity to interference Test fre- Volume Service Modulation Power max. Distance Immunity test quency (MHz) level (V/m) (MHz) 380 - 390 TETRA 400 Pulse modula- tion 18 Hz 430 - 470...
  • Page 68: Working Clearances

    5 Electromagnetic compatibility Dentsply Sirona 5.4 Working clearances Installation requirements Intego Working clearances The UNIT is intended for operation in an electromagnetic environment, where radiated RF interference is checked. The customer or the user of the UNIT can help prevent electromagnetic interference by maintaining...
  • Page 69: Checklist

    We recommend performing an inspection of the circumstances on location at least 4 weeks prior to installation. The checklist should help you when doing this. This can help ensure a smooth procedure on the day that the Intego / Intego Pro is actually installed. Installation location: ●...
  • Page 70: Construction Requirements

    ● Compensating plates can be used for slight unevenness, no mounting plates required. ☐ ● Adapter plates: Intego Pro REF 64 32 061, Intego REF 65 42 018: Can be used to replace ☐ certain C-line dental treatment centers, for details see Mounting plates  [→ 52] ●...
  • Page 71: It Hardware

    Dentsply Sirona 6 Checklist Installation requirements Intego 6.3 IT hardware IT hardware Mode of operation ☑ ● PC in treatment room ☐ PC system requirements: ☑ IT hardware and software requirements are described in the document "Installation notes and ☐...
  • Page 72: Network

    ☐ ● Network connection for external PC available. ☐ IMPORTANT! The use of routers between Intego / Intego Pro and the treatment center PC must be avoided. ● Network configuration plan available. ☐ ● Network jacks have been certified. ☐...
  • Page 73: Data Processing

    ● Is there a DHCP server (dynamic TCP/IP address assignment)? ☐ Yes ☐ No IMPORTANT! A static address should be assigned to Intego / Intego Pro! It must not lie in the dynamic address range! ● Intego / Intego Pro: _____ . _____ . _____ . ____ ●...
  • Page 74 We reserve the right to make any alterations which may be required due to technical improvements. © Sirona Dental Systems GmbH Sprache: englisch Printed in Germany D3543.021.01.09.02      12.2018 Ä.-Nr.:  126 478 Sirona Dental Systems GmbH 64 57 092 D3543 Fabrikstr. 31 Order No   ...