11.8
Design
Table 11- 25 Design
Description
Dimension and weight
Process connectors
Electrical connection
Material
Measuring tube design
FC410 with Modbus
Operating Instructions, 02/2016, A5E33120874-AC
Measuring tubes
Process connectors
Sensor enclosure
Transmitter enclosure
Specification
See Dimensions and weight (Page 111)
EN1092-1 B1, PN16, PN40, PN63, PN100,
•
PN160
EN1092-1 D (gasket groove), PN40, PN63,
•
PN100, PN160
ISO 228-1 G *
•
ASME B1.20.1 NPT *
•
ASME B16.5, Cl 150, Cl 300, Cl 600, Cl 900
•
DIN 11851 **
•
DIN 32676 *
•
DIN 11864-1A **, DIN 11864-2C (inch) **, DIN
•
11864-3A **
ISO 2852 **
•
ISO 2853 **
•
JIS B 2220, 10K, 20K, 40K, 62K
•
M12 connector with 4-wire cable
•
Standard cable with polymer / brass / stain-
•
less steel cable glands (metric or NPT)
Armored cable with stainless steel armored
•
cable glands (metric or NPT)
Conduit entries (metric or NPT)
•
AISI 316L / W1.4404
•
Hastelloy C22 / UNS N06022
•
Standard:
•
–
AISI 316L / W1.4435 or W1.4404
–
Hastelloy C22 / UNS N06022
Hygienic:
•
–
AISI 316L / W1.4435
AISI 304 / W1.4301
Aluminum with corrosion-resistant coating
Split flow through 2 parallel tubes with combined
cross-section area 50% of the nominal pipe
The measuring tubes are bent in a trapezoidal
curve
Technical data
11.8 Design
99