Avoid vibrations
● Make sure that no valves or pumps upstream of the flowmeter cavitates or sends
vibration into the sensor.
● Decouple vibrating pipeline from the flowmeter using flexible tube or couplings
Image 4-7
Image 4-8
Avoid cross talk
If operating more than one flowmeter in one or multiple interconnected pipelines there is a
risk of cross talk.
Prevent cross talk in one of the following ways:
● Mount sensors on separate frames
● Decouple the pipeline using flexible tube or couplings
Image 4-9
Image 4-10
FC410 with Modbus
Operating Instructions, 02/2016, A5E33120874-AC
Non-flexible pipes not recommended in vibrating environment
Flexible pipes recommended in vibrating environment
High risk of cross talk when using non-flexible pipes
Low risk of cross talk when using flexible pipes