Siemens SITRANS FC410 Operating Instructions Manual page 132

Coriolis flowmeters with modbus
Hide thumbs Also See for SITRANS FC410:
Table of Contents

Advertisement

Modbus holding registers
A.3 Modbus holding registers tables
Modbus
Data type /
address
Size [bytes]
2207
Unsigned /
2
2214
Unsigned /
2
2215
Unsigned /
2
2216
Unsigned /
2
2217
Unsigned /
2
2218
Unsigned /
2
Table A- 12
Zero point adjustment
Modbus
Data type /
address
Size [bytes]
2132
Unsigned /
2
2133
Float / 4
2135
Unsigned /
2
2136
Float / 4
130
Parameter
Description
Minimum Filtering
The filtering time is reset
Time
each time hysteresis band is
exceeded
Pickup Amplitude
Enable/disable pickup
Filter
amplitude filter.
0 = Disable
1 = Enable
Bad Measurement
Number of bad measure-
Count
ments counted during the
last period
Filter Iteration
Set the number of times to
repeat the same filter.
Increasing the number will
increase the damping.
Active only if Filter Time
Constant is set to 7.
Bandwidth Factor
Increase the Bandwidth
Factor to reduce the LP (low
pass) bandwidth filtering.
Active only if Filter Time
Constant is set to 7.
Filter Pole Shift
Configure the bandwidth
and damping in the stop
band. A high number will
give a small bandwidth and
an increased damping in the
stop band.
Active only if Filter Time
Constant is set to 7.
Parameter
Description
Zero Point
Select zero-point adjust-
Adjustment
ment method. Automatic
zero point adjustment is
recommended.
Manual Zero Point
Enter agreed zero point
Offset
offset value for manual zero
point adjustment mode.
Zero Point Duration
Define duration of zero point
adjustment.
Standard Deviation
Standard deviation during
auto zero point adjustment
0 = Auto
1 = Manual
Operating Instructions, 02/2016, A5E33120874-AC
Default value
Value range Access
[unit]
10 [ms cycles] 0 to 65535
1
0 to 1
0
0 - 65535
3
1 to 5
2
0 to 4
2
1 to 5
Default value
Value range Access
[unit]
0
0 to 1
0 [kg/s]
0 to 1023
30 [s]
1 to 999
0 [kg/s]
-1023 to
+1023
FC410 with Modbus
level
Read /
Write
Read /
Write
Read Only
Read /
Write
Read /
Write
Read /
Write
level
Read /
Write
Read /
Write
Read /
Write
Read only