Ped - Siemens SITRANS FC410 Operating Instructions Manual

Coriolis flowmeters with modbus
Hide thumbs Also See for SITRANS FC410:
Table of Contents

Advertisement

Description
IECEx
EAC Ex
FM
Hygienic version
Pressure equipment
Marine approval
11.14

PED

The pressure equipment directive 97/23/EC applies to the alignment of the statutory orders
of the European member states for pressure equipment. Such equipment in the sense of the
directive includes vessels, pipelines and accessories with a maximum allowable pressure of
more than 0.5 bar above atmospheric. Flowmeters are considered as piping.
A detailed risk analysis of the flowmeter has been performed in accordance with the PED
97/23/EC. All risks are assessed to be "none" provided that the procedures and standards
referenced in these operating instructions are observed.
FC410 with Modbus
Operating Instructions, 02/2016, A5E33120874-AC
Specification
FC410 flowmeter (can be installed in Zone 1 for gas and Zone 20/21 for
dust):
Certificate: IECEx SIR 11.0149X
For gas:
Ex d ia IIC T* Ga/Gb
Ex d IIC T* Ga/Gb
(Ga/Gb: Zone 0 in pipe and Zone 1 in environment)
For dust:
Ex ta IIIC T* °C Da
Ex tb IIIC T* °C Db
(Zone 20 ("ta") process and ambient temperature limited in comparison with
Zone 21 ("tb")
(Ta = -40°C to +60°C)
* Temperature class (dependent on the process temperature and the ambi-
ent temperature, see Conditions of Certification, Section 2.3)
FC410 flowmeter / -40°C ≤ Tamb ≤ ** °C
1Ex d ia IIC T* Ga/Gb
Ex ta IIIC T** °C Da
Ex tb IIIC T** °C Db
Class I, II, III Division 1
Groups A, B, C, D, E, F, G
See Control drawing: A5E31205486A
3A
EHEDG
EC1935:2004 and 2023:2006 (food contact material: stainless steel)
97/23/EC Pressure Equipment Directive (PED)
Canadian Registration Number (CRN)
ABS - American Bureau of Shipping (USA)
BV - Bureau Veritas (France)
DNV - Det Norske Veritas (Norway)
GL - Germanischer Lloyd (Germany)
Lloyds Register (Worldwide)
Technical data
11.14 PED
103

Hide quick links:

Advertisement

Table of Contents
loading