Sensor Dimension Dependent Default Settings - Siemens SITRANS FC410 Operating Instructions Manual

Coriolis flowmeters with modbus
Hide thumbs Also See for SITRANS FC410:
Table of Contents

Advertisement

Sensor dimension dependent default settings

Massflow
Sensor dimension
Low Flow Cut-Off
DN 15
DN 25
DN 50
DN 80
Volumeflow
Sensor dimension
Low Flow Cut-Off
DN 15
DN 25
DN 50
DN 80
Zero Point Adjustment
Sensor dimension
Standard Deviation Limit
DN 15
DN 25
DN 50
DN 80
Offset Limit
DN 15
DN 25
DN 50
DN 80
FC410 with Modbus
Operating Instructions, 02/2016, A5E33120874-AC
Default value
0.00884
0.0245
0.0982
0.251
Default value
0.00000884
0.0000245
0.0000982
0.000251
Default value
0.0004
0.004
0.015
0.019
0.031944444
0.010277778
0.144444444
0.377777778
Unit
Range
kg/s
0 to +8.84
kg/s
0 to +24.5
kg/s
0 to +98.2
kg/s
0 to +351
Unit
Range
m
/s
0 to +0.00884
3
m
/s
0 to +0.0245
3
m
/s
0 to +0.0982
3
m
/s
0 to +0.251
3
Unit
Range
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
kg/s
B
139