Hastelloy Sensors - Siemens SITRANS FC410 Operating Instructions Manual

Coriolis flowmeters with modbus
Hide thumbs Also See for SITRANS FC410:
Table of Contents

Advertisement

Technical data
11.7 Pressure - temperature ratings
Note
Test pressure
Maximum allowable test pressure (MATP) for the flowmeter and process connection is 1.5
times the nominal pressure up to 150 bar (2176 psi).
11.7.2

Hastelloy sensors

Table 11- 21 EN1092-1 [bar]
PN (bar)
16
40
63
100
160
Table 11- 22 ISO228-G and ASME B1.20.1 NPT [bar]
PN (bar)
100
160
Table 11- 23 ASME B16.5 [bar]
Class
150
300
600
900
Table 11- 24 DIN 11851 [bar]
PN (bar) / DN
25 / 50-100
40 / 10-40
98
-50
0
16.0
16.0
40.0
40.0
63.0
63.0
100.0
100.0
160.0
160.0
-50
0
100.0
100.0
160.0
160.0
-50
0
20.0
20..
51.7
51.7
103.4
103.4
155.1
155.1
-50
0
25
25
40
40
Temperature TS (°C)
50
100
16.0
16.0
40.0
40.0
63.0
63.0
100.0
100.0
153.0
145.0
Temperature TS (°C)
50
100
100.0
100.0
153.0
145.0
Temperature TS (°C)
50
100
19.5
17.7
51.7
51.5
103.4
103.0
153.0
145.0
Temperature TS (°C)
50
100
25
25
40
40
Operating Instructions, 02/2016, A5E33120874-AC
150
200
16.0
16.0
40.0
40.0
63.0
63.0
100.0
100.0
134.0
125.0
150
200
100.0
100.0
134.0
125.0
150
200
15.8
13.8
50.3
48.6
100.3
97.2
134.0
125.0
140
25
40
FC410 with Modbus

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents