Bfd For Is-Is Configuration Example - HPE 5800 Series Configuration Manual

Layer 3 - ip routing
Hide thumbs Also See for 5800 Series:
Table of Contents

Advertisement

[SwitchB-Vlan-interface200] isis authentication-mode md5 t5Hr
[SwitchB-Vlan-interface200] quit
[SwitchC] interface vlan-interface 200
[SwitchC-Vlan-interface200] isis authentication-mode md5 t5Hr
[SwitchC-Vlan-interface200] quit
# Specify the MD5 authentication mode and password hSec on VLAN-interface 300 of Switch
D and on VLAN-interface 300 of Switch C.
[SwitchC] interface vlan-interface 300
[SwitchC-Vlan-interface300] isis authentication-mode md5 hSec
[SwitchC-Vlan-interface300] quit
[SwitchD] interface vlan-interface 300
[SwitchD-Vlan-interface300] isis authentication-mode md5 hSec
[SwitchD-Vlan-interface300] quit
Configure area authentication. Specify the MD5 authentication mode and password 10Sec on
4.
Switch A, Switch B, and Switch C.
[SwitchA] isis 1
[SwitchA-isis-1] area-authentication-mode md5 10Sec
[SwitchA-isis-1] quit
[SwitchB] isis 1
[SwitchB-isis-1] area-authentication-mode md5 10Sec
[SwitchB-isis-1] quit
[SwitchC] isis 1
[SwitchC-isis-1] area-authentication-mode md5 10Sec
[SwitchC-isis-1] quit
Configure routing domain authentication. Specify the MD5 authentication mode and password
5.
1020Sec on Switch C and Switch D.
[SwitchC] isis 1
[SwitchC-isis-1] domain-authentication-mode md5 1020Sec
[SwitchC-isis-1] quit
[SwitchD] isis 1
[SwitchD-isis-1] domain-authentication-mode md5 1020Sec

BFD for IS-IS configuration example

Network requirements
As shown in
to each other at the network layer.
After the link over which Switch A and Switch B communicate through the Layer-2 switch fails,
BFD can quickly detect the failure and notify IS-IS of the failure. Switch A and Switch B then
communicate through Switch C.
Figure
56, IS-IS is enabled on Switch A, Switch B and Switch C that are reachable
164