WAN Configuration
Table 48: USP Dialog Box - Frame Relay Parameters (continued)
Field
Last Fault Message
Time Since Fault
Backup Interface

Sub-Frame-Relays

The Sub-Interfaces tab of the USP dialog box provides information about the configuration of
Frame Relay sub-interfaces in the USP.
To view the Sub-Interfaces tab of the USP dialog box:
1. Click a USP symbol in the Chassis View or Tree View. The USP dialog box opens with the
Serial Port tab.
2. Click Sub-Interfaces. The Sub-Interfaces tab of the USP dialog box opens.
136 Avaya Integrated Management Release 4.0.1 Software Update Manager
Description
The type of error last occurring on the interface. Possible values are:
Unknown Error
Receive Short
Receive Long
Illegal Address
Unknown Address
DLCMI Protocol Error
DLCMI Unknown IE
DLCMI Sequence Error
DLCMI Unknown Rpt
No Error Since Reset
The amount of time the system was up before the last error
occurred.
The interface configured to back up this interface.