Yamaha STAR XVS95CE 2DX1 2014 Service Manual page 415

Xvs95ce(c)
Table of Contents

Advertisement

SELF-DIAGNOSTIC FUNCTION AND DIAGNOSTIC CODE TABLE
Diagnostic
code No.
61
Malfunction history code
display
• No history
• History exists
62
Malfunction history code
erasure
• No history
• History exists
63
Malfunction code rein-
statement (for fault code
No. 24 only)
• No malfunction code
• Malfunction code exists
70
Control number
Diagnostic code: actuator operation table
Diagnostic
code No.
30
Front cylinder ignition coil
Item
00
Fault codes 12–70
• (If more than one code
number is detected, the
display alternates every
two seconds to show all
the detected code num-
bers.
When all code numbers
are shown, the display
repeats the same pro-
cess.)
00
• Displays the total num-
ber of malfunctions, in-
cluding the current
malfunction, that have
occurred since the histo-
ry was last erased. (For
example, if there have
been three malfunc-
tions, "03" is displayed.)
00
Fault code 24
0–254 [-]
Item
Actuates the front cylinder
ignition coil five times at
one-second intervals.
Illuminates the engine
trouble warning light and
Yamaha diagnostic tool
warning light.
8-8
Display
To erase the history, set
the start/engine stop
switch from " " to " ".
To reinstate, set the
start/engine stop switch
from " " to " ".
Actuation
Check that a spark is gen-
erated five times.
• Connect an ignition
checker.
Procedure
Procedure