Modules
Option Modules (MO)
If an error occurs during software installation, clear the Flash memory and reinstall
the software. Follow these instructions:
Turn the PABX off
Set Switch 1 (FE) to ON
Turn the PABX on again
Wait for F and E to show on the display
Turn the PABX off
Set switch 1 (FE) to OFF again
Turn on the PABX
DIP Switch 2 (S401)
It is recommended that you do not change the DIP Switch 2 default setting.
Table 3-22
Switch
7-segment Display Readings (H801)
Table 3-23
TME1 module display readings
Display
8
Continuous
]
Continuous
3-32
TME1 module, DIP switch 2
Procedure
1
DSP - BIO
2
Reserved
3
Reserved
4
Battery connection
5
MODCK2
6
7
MODCK1
8
E1 Interface impedance
Reading
Module is powered.
Starting TME1 module.
WDI
For internal distribution only
Default
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
Meaning
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual