DIP Switch Positions for the TME1 Module
Figure 3-19
By changing the positions of the DIP switches to ON (120 Ohms) or OFF (75 Ohms)
the following settings can be configured:
DIP Switch 1 (S201)
It allows you to clean the Flash memory, select the baud rate and execute an auto-
test.
Table 3-21
TME1 module, DIP switch 1
Switch Pro-
ce-
dure
1
FE
Delete Flash memory
2
EST Extended autotest
3
BR1
Baud rate configura-
4
BR2
5
BR3
6
RES
7
RES
8
RES
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
DIP Switch for the TME1 Module
Meaning
ON - Deletes Flash memory when the PABX is turned
on
OFF - System will work as usual (default).
ON - Activates autotest
OFF - Skips autotest (default).
(3) OFF , (4) OFF and (5) OFF: 9600 bps
(3) OFF , (4) OFF and (5) ON: 19200 bps
tion
(3) OFF , (4) ON and (5) OFF: 38400 bps
(3) OFF , (4) ON and (5) ON: 57600 bps (default)
Possible Settings