For internal distribution only
Step
3.
4.
5.
6.
7.
8.
The length of the cables between the X2 connector and the PABX must not exceed
32.8 feet (10 meters).
Entrance Telephone Mode
Step
1.
2.
3.
4.
5.
6.
7.
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Procedure
Connect the interface to the Entrance Telephone extension by using con-
tacts 1 and 2 on the X2 connector.
To activate Pager mode, lift the handset at one of the answering exten-
sions and dial the Entrance Telephone number. Once the appropriate
number is dialed, the calling extension is connected to the Entrance Tele-
phone, but without voice capability.
For voice capability, dial "8" . The ambient sound will stop and you will be
able to leave a message. The sound will be amplified in all speakers con-
nected to the amplifier.
To disable voice capability, dial "9" . If the sound is not disabled manually,
it will timeout automatically after 15 seconds. To enable the automatic
timeout, set jumper 3 (J3) to OFF .
"Performing a Visual Inspection" on page 4-48.
Configure the required data (see "Operation" on page 6-1).
Procedure
Set jumper 1 (J1) to OFF (see"Entrance Telephone Interface" on page 3-
49).
Configure the system for Entrance Telephone/Door Opener mode and
specify the extensions for answering calls. Specify also at which exten-
sion the interface will be installed.
Connect the interface to the Entrance Telephone extension by using con-
tacts 1 and 2 on the X2 connector.
Connect the Entrance Telephone to contacts 3 and 4 on the X6 connector,
wiring it as instructed by the manufacturer.
When the person at the door presses the Entrance Telephone button it
causes it to ring at extensions configured for answering calls.
When an extension answers the call, the voice capability is automatically
enabled.
Dial the code for the Door Opener.
To disable voice capability the attendant extension must dial "9" .
To enable voice again the attendant extension must dial "5" .
If the sound is not disable manually, it will automatically timeout after 5
minutes.