System Data
Technical Data
Table 2-4
Technical Data
Element
Call Voltage
Dialing Modes for Calls to other Public or Private Exchanges:
MF Transmission Level:
●
Low Group
*
High Group
*
Pre-Emphasis
Pulse Duration
**
Inter-digit Pause
**
DP (Dial Pulse):
●
Pulse/Pause
Ra-
tio
**
Inter-digit Pause
**
Open loop isola-
tion
resistance
between a/b or a/
ground
or
b/
ground
Closed loop line
resistance/contin-
uous loop current
Incoming Call De-
tection
*〉
Values vary according to the country. The values shown are specifically for Brazil.
**〉
Values depend on the country settings, which are configurable. The values shown are default values for Brazil.
Values shown are approximate. When making connections, consider the specific
level of tolerance that applies.
2-8
HiPath 1120
U3:
40 V
/60Hz
rms
65 V
/20Hz (CND)
rms
65 V
/25Hz (SPA)
rms
42 V
/25Hz (RSA)
rms
2:1 (approximately 70:30ms = 10 Hz)
Complies with national requirements/standards
HiPath 1130 HiPath 1150 HiPath 1190
50 V
+ 97 V
AC
42 V
+ 85.8 V
AC
DC
-11 dBm
-9 dBm
2 dB
90ms min.
90ms min.
800ms
> 10MΩ
> 9V
RMS
A31003-K1250-S100-12-7619
For internal distribution only
/ 0.13A - 25Hz
DC
/ 0.13A - 25Hz (RSA)
HiPath 1100, Service Manual