HP 1652B Programming Reference Manual page 86

Logic
Hide thumbs Also See for HP 1652B:
Table of Contents

Advertisement

DATA
I
Note d
System Commands
Information Bytes. In the Transitional timing mode the logic analyzer
performs the following steps to obtain the information bytes:
1. Four samples of data are taken at 10 nanosecond intervals. The data is
stored and the value of the last sample is retained.
2. Four more samples of data are taken. If any of these four samples differ
from the last sample of the step 1, then these four samples are stored
and the last value is once again retained.
3. If all four samples of step 2 are the same as the last sample taken in step
process will continue until a group of four samples is found which
differs from the retained sample. At this time, the count will be stored
sample of the four once again retained for comparison.
The stored count indicates the number of
between the old data and the new data.
The rows of the acquisition data may, therefore, be either four rows of
data followed by four more rows of data, or four rows of data followed by
four rows of count. Rows of count will always be followed by four rows of
data except for the last row, which may be either data or count.
This process is performed on a pod-by-pod basis. The individual status
bits will indicate what each pod is doing.