HP 1652B Programming Reference Manual page 244

Logic
Hide thumbs Also See for HP 1652B:
Table of Contents

Advertisement

Command Syntax:
where:
c label name >
Example:
HP 1652B/l653B
Programming Reference
The PAlTern command allows you to construct a pattern recognizer term
for the timing analyzer trigger on a per label basis. Each command deals
with only one label in the given pattern; therefore, a complete timing trace
specification could require several commands. Since a label can contain
up to 32 bits, the range of the pattern value will
The value may be expressed in binary (#B), octal (#a), hexadecimal
(#H) or decimal (default). When the value of a pattern is expressed in
binary, it represents the bit values for the label inside the pattern
recognizer term. Since a pattern value can contain don't cares, the
pattern specification parameter is handled as a string of characters
instead of a number.
The PAlTern query returns the pattern specification for the specified
label in the base previously defmed for the label.
:: = string of up to 6 alphanumeric characters
:: = "{#B(OI 1 IX) . . 1
OUTPUT XXX; ":MACHINEl:TTRACE:PATTERN
be
between 0 and (232)-1,
. . I
. .)"
'DATA', '255'"
command/query

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 1653b

Table of Contents