AudioCodes Mediant 800B User Manual page 944

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Parameter
Web: AGC Redirection
EMS: Redirection
CLI: AGC-redirection
[AGCRedirection]
Web: AGC Target Energy
EMS: Target Energy
CLI: AGC-target-energy
[AGCTargetEnergy]
EMS: Minimal Gain
CLI: AGC-min-gain
[AGCMinGain]
EMS: Maximal Gain
CLI: AGC-max-gain
[AGCMaxGain]
EMS: Disable Fast Adaptation
CLI: AGC-disable-fast-adaptation
[AGCDisableFastAdaptation]
Energy Detector Parameters
Enable Energy Detector
CLI: energy-detector-enable
[EnableEnergyDetector]
Energy Detector Quality Factor
CLI: energy-detector-sensitivity
[EnergyDetectorQualityFactor]
Energy Detector Threshold
CLI: energy-detector-threshold
[EnergyDetectorThreshold]
Pattern Detection Parameters
Note: For an overview on the pattern detector feature for TDM tunneling, see DSP Pattern Detector
on page 330.
User's Manual
[28] 28 = 35.00 dB/sec
[29] 29 = 40.00 dB/sec
[30] 30 = 50.00 dB/sec
[31] 31 = 70.00 dB/sec
Determines the AGC direction.
[0] 0 = (Default) AGC works on signals from the TDM
side.
[1] 1 = AGC works on signals from the IP side.
Defines the signal energy value (dBm) that the AGC
attempts to attain.
The valid range is 0 to -63 dBm. The default is -19 dBm.
Defines the minimum gain (in dB) by the AGC when
activated.
The range is 0 to -31. The default is -20.
Note: For this parameter to take effect, a device reset is
required.
Defines the maximum gain (in dB) by the AGC when
activated.
The range is 0 to 18. The default is 15.
Note: For this parameter to take effect, a device reset is
required.
Enables the AGC Fast Adaptation mode.
[0] = Disable (default)
[1] = Enable
Note: For this parameter to take effect, a device reset is
required.
Enables the Energy Detector feature. This feature generates
events (notifications) when the signal received from the
PSTN is higher or lower than a user-defined threshold
(defined by the EnergyDetectorThreshold parameter).
[0] Disable (default)
[1] Enable
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity
and 10 the highest sensitivity. The default is 4.
Defines the Energy Detector's threshold. A signal below or
above this threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm + (EnergyDetectorThreshold *
6)
The valid value range is 0 to 7. The default is 3 (i.e., -26
dBm).
944
Mediant 800B Gateway and E-SBC
Description
Document #: LTRT-10278

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents