Establishing A Cli Session - AudioCodes Mediant 800B User Manual

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

To configure RSA public keys for Linux (using OpenSSH 4.3):
1.
Run the following command to create a new key in the admin.key file and to save the
public portion to the admin.key.pub file:
ssh-keygen -f admin.key -N "" -b 1024
2.
Open the admin.key.pub file, and then copy the encoded string from "ssh-rsa" to the
white space.
3.
Open the Telnet/SSH Settings page (Configuration tab > System menu >
Management > Telnet/SSH Settings), and then paste the value copied in Step 2 into
the 'Admin Key' field.
4.
Click Submit.
5.
Connect to the device with SSH, using the following command:
ssh -i admin.key xx.xx.xx.xx
where xx.xx.xx.xx is the device's IP address. RSA-key negotiation occurs
automatically and no password is required.
7.3

Establishing a CLI Session

The device's CLI can be accessed using any of the following methods:
RS-232: The device can be accessed through its RS-232 serial port, by connecting a
VT100 terminal to it or using a terminal emulation program (e.g., HyperTerminal) with
a PC. For connecting to the CLI through RS-232, see ''CLI'' on page 31.
Secure SHell (SSH): The device can be accessed through its Ethernet interface by
the SSH protocol using SSH client software. A popular and freeware SSH client
software is Putty, which can be downloaded from
http://www.chiark.greenend.org.uk/~sgtatham/putty/download.
Telnet: The device can be accessed through its Ethernet interface by the Telnet
protocol using Telnet client software.The following procedure describes how to
establish a CLI session with the device.
The following procedure describes how to access the CLI through Telnet/SSH.
Note:
The CLI login credentials are the same as all the device's other management
interfaces (such as Web interface). The default username and password is "Admin"
and "Admin" (case-sensitive), respectively. For configuring login credentials, see
''Configuring Web User Accounts'' on page 54.
To establish a CLI session with the device:
1.
Connect the device to the network.
2.
Establish a Telnet or SSH session using the device's OAMP IP address.
3.
Log in to the session using the username and password assigned to the Admin user of
the Web interface:
a.
At the Username prompt, type the username, and then press Enter:
Username: Admin
b.
At the Password prompt, type the password, and then press Enter:
Password: Admin
c.
At the prompt, type the following, and then press Enter:
> enable
d.
At the prompt, type the password again, and then press Enter:
Password: Admin
User's Manual
Mediant 800B Gateway and E-SBC
72
Document #: LTRT-10278

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents