Parameter
Web: Deny Access On Fail Count
[DenyAccessOnFailCount]
Web: Deny Authentication Timer
EMS: WEB Deny Authentication
Timer
[DenyAuthenticationTimer]
Web: Display Login Information
[DisplayLoginInformation]
[EnableMgmtTwoFactorAuthenti
cation]
EMS: HTTPS Port
CLI: http-port
[HTTPport]
EMS: Disable WEB Config
[DisableWebConfig]
Version 6.8
set in the Web Users table.
Defines the maximum number of failed login attempts, after
which the requesting IP address is blocked.
The valid value range is 0 to 10. The values 0 and 1 mean
immediate block. The default is 3.
Defines the duration (in seconds) for which login to the Web
interface is denied from a specific IP address (for all users)
when the number of failed login attempts has exceeded the
maximum. This maximum is defined by the
DenyAccessOnFailCount parameter. Only after this time expires
can users attempt to login from this same IP address.
The valid value is 0 to 100000, where 0 means that login is not
denied regardless of number of failed login attempts. The
default is 60.
Enables display of user's login information on each successful
login attempt.
[0] = Disable (default)
[1] = Enable
Enables Web login authentication using a third-party, smart
card.
[0] = Disable (default)
[1] = Enable
When enabled, the device retrieves the Web user's login
username from the smart card, which is automatically displayed
(read-only) in the Web Login screen; the user is then required to
provide only the login password.
Typically, a TLS connection is established between the smart
card and the device's Web interface, and a RADIUS server is
implemented to authenticate the password with the username.
Thus, this feature implements a two-factor authentication - what
the user has (the physical card) and what the user knows (i.e.,
the login password).
Defines the LAN HTTP port for Web management (default is
80). To enable Web management from the LAN, configure the
desired port.
Note: For this parameter to take effect, a device reset is
required.
Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified. In
addition, the following pages can't be accessed: 'Web User
Accounts', 'Certificates', 'Regional Settings', 'Maintenance
Actions' and all file-loading pages ('Load Auxiliary Files',
'Software Upgrade Wizard', and 'Configuration File').
Note: For this parameter to take effect, a device reset is
required.