5. PARAMETERS

5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])

No.
Symbol
PF06
*FOP5
Function selection F-5
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PF12
DBT
Electronic dynamic brake operating time
Set an operating time for the electronic dynamic brake.
PF21
DRT
Drive recorder switching time setting
Set the drive recorder switching time.
When USB communication is cut during the use of a graph function, the function will be
changed to the drive recorder function after the time set in this parameter has passed.
When a value from "1" to "32767" is set, the function will be switched to the drive recorder
function after the set time.
However, when "0" is set, the function will be switched to the drive recorder function after 600
s.
When "-1" is set, the drive recorder function is disabled.
PF23
OSCL1
Vibration tough drive - Oscillation detection level
Set filter readjustment sensitivity levels of [Pr. PB13 Machine resonance suppression filter 1]
and [Pr. PB15 Machine resonance suppression filter 2] while the vibration tough drive is
enabled.
However, setting "0" will be 50%.
Example: When you set "50" in the parameter, the filter will be readjusted at the time of 50%
or higher oscillation level.
PF24
*OSCL2
Vibration tough drive function selection
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Name and function
Explanation
Electronic dynamic brake selection
0: Disabled
3: Automatic (enabled only for specified servo motors)
Refer to the following table for the specified servo motors.
Series
HG-KN
HG-KN053/HG-KN13/HG-KN23/HG-KN43
HG-SN
HG-SN52
For manufacturer setting
Explanation
Oscillation detection alarm selection
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation
detection.
2: Oscillation detection function is disabled.
Select whether to generate an alarm or a warning when an
oscillation continues at a filter readjustment sensitivity level of [Pr.
PF23].
The digit is continuously enabled regardless of the vibration tough
drive in [Pr. PA20].
For manufacturer setting
Servo motor
5 - 39
Initial
Setting
value
range
[unit]
Refer to the
"Name and
Initial
function" column.
value
3h
0h
0h
0h
2000
0 to
[ms]
10000
0
-1 to
[s]
32767
50
0 to 100
[%]
Refer to the
"Name and
Initial
function" column.
value
0h
0h
0h
0h