5. PARAMETERS
No.
Symbol
PB26
*CDP
Gain switching function
Select the gain switching condition.
Set conditions to enable the gain switching values set in [Pr. PB29] to [Pr. PB36] and [Pr.
PB56] to [Pr. PB60].
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PB27
CDL
Gain switching condition
Set the value of the gain switching (command frequency, droop pulses, or servo motor speed)
selected in [Pr. PB26].
The set value unit differs depending on the switching condition item. (Refer to section 7.2.3.)
PB28
CDT
Gain switching time constant
Set the time constant until the gains switch in response to the conditions set in [Pr. PB26] and
[Pr. PB27].
PB29
GD2B
Load to motor inertia ratio after gain switching
Set the load to motor inertia ratio for when gain switching is enabled.
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain adjustment
mode selection" in [Pr. PA08].
PB30
PG2B
Position loop gain after gain switching
Set the position loop gain for when the gain switching is enabled.
When you set a value smaller than 1.0 rad/s, the value will be the same as the value set in [Pr.
PB08].
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain adjustment
mode selection" in [Pr. PA08].
PB31
VG2B
Speed loop gain after gain switching
Set the speed loop gain for when the gain switching is enabled.
When you set a value smaller than 20 rad/s, the value will be the same as the value set in [Pr.
PB09].
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain adjustment
mode selection" in [Pr. PA08].
Name and function
Explanation
Gain switching selection
0: Disabled
1: Control command from controller is enabled
2: Command frequency
3: Droop pulses
4: Servo motor speed
Gain switching condition selection
0: Gain after switching is enabled with gain switching condition or
more
1: Gain after switching is enabled with gain switching condition or
less
Gain switching time constant disabled condition selection
0: Switching time constant is enabled.
1: Switching time constant is disabled.
2: Return time constant is disabled.
Refer to section 7.2.4 for details.
For manufacturer setting
5 - 24
Initial
Setting
value
range
[Unit]
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h
10
0 to
65535
[kpulse/s]
/[pulse]
/[r/min]
1
0 to 100
[ms]
7.00
0.00 to
300.00
[Multiplier]
0.0
0.0 to
[rad/s]
2000.0
0
0 to
[rad/s]
65535